Sharp ND-U230C1 Installation And User Manual Download Page 5

Ver. 2.0U Dec. 4, 2008 

 

 

- 5 -                                                                    Installation Manual for PV modules 

 
 

 
 
 
 
 

e

e

e

e

g

g

g

g

s

s

s

s

Figure 12 (NT/NE series) 

Figure 9 (ND series) 

u

u

u

u

Figure 12 (NT/NE series) 

Figure 9 (ND series) 

Figure 10 (NT/NE series) 

8.3” (210 mm) 

 g 

18.5” (470 mm) 

Figure 11 (ND series) 

9.3” (235 mm) 

 e 

19.4” (495 mm) 

Figure 13 (ND series) 

9.3” (235 mm) 

 s 

 19.4” (495 mm) 

8.3” (210 mm) 

 u 

  18.5” (470 mm) 

Figure 14 (NT/NE series) 

Summary of Contents for ND-U230C1

Page 1: ...thal shock whether the PV modules are connected or not 4 PV modules produce electricity when sufficient sunlight or other light source illuminates the module When modules are connected in series voltage is cumulative When modules are connected in parallel current is cumulative PV systems can produce high voltage and current which could present an increased hazard and may cause serious injury or de...

Page 2: ...oves with padding in the palm and finger areas 14 Do not drop the PV module or allow objects to fall on the PV module 15 Do not lift the PV module by only one side The frame may bend Always use two hands to lift and carry the PV module on the long side of the frame 16 Some PV modules incorporate one or more support bars on the back of the module Do not mount or carry the PV module using the suppor...

Page 3: ...ions below In a connection of this type the hardware such as a star washer must score the frame surface to make positive electrical contact with the frame The ground wire must not be smaller than No 14 AWG 2 1 mm2 and should be sized according to the NEC Hardware used must be compatible with the mounting structure material to avoid galvanic corrosion If using the SHARP On Energy mounting system th...

Page 4: ...5 11 12 The modules may be mounted using clamps designed for solar modules as shown in Figures 5 Note that the clamp positions are important the clamp centerlines must be between 9 3 235 mm and 19 4 495 mm regarding ND series as shown in Figure 11 and 8 3 210mm and 18 5 470mm regarding NT NE series as shown in Figure 12 from the end of the module The module must be supported along the length of th...

Page 5: ... s Figure 12 NT NE series Figure 9 ND series u u u u Figure 12 NT NE series Figure 9 ND series Figure 10 NT NE series 8 3 210 mm g 18 5 470 mm Figure 11 ND series 9 3 235 mm e 19 4 495 mm Figure 13 ND series 9 3 235 mm s 19 4 495 mm 8 3 210 mm u 18 5 470 mm Figure 14 NT NE series ...

Page 6: ...m power Ipmax 7 66 A 7 54 A 7 48 A 7 25 A 7 04 A Maximum System Voltage 600 V 600 V 600 V 600 V 600 V Minimum Blocking diode 15 A 15 A 15 A 15 A 15 A Series Fuse 15 A 15 A 15 A 15 A 15 A NT 175UC1 NT 170UC1 NE 170UC1 NE 165UC1 Maximum Power Pmax 175 0 W 142 0 W 170 0 W 165 0 W Open Circuit Voltage Voc 44 4 V 43 2 V 43 2 V 43 1 V Short Circuit Current Isc 5 40 A 5 47 A 5 47 A 5 31 A Voltage at maxi...

Page 7: ...nship and materials and Sharp agrees that for a period of one 1 year from the date of purchase by the consumer that Sharp will at its option either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period s set forth below Limited Warranty For Power The warranty period with respect to ...

Page 8: ...improper voltage or power surges or abnormal environmental conditions such as acid rain or other pollution c the components in the construction base on which the module is mounted are defective d external corrosion mold discoloration or the like occurs e the product has been moved from its original installation f the model number or serial number of the product is altered removed or rendered illeg...