37
US
Basic Operation
PC Operation
PC Operation
PC connection
Connect with RS-232C cross cable between the PC COM port (RS-232C connector) and the RS-
232C INPUT terminal on the back of monitor.
Connect with RS-232C cross cable between the PC COM port (RS-232C connector) and the RS-
232C INPUT terminal on the back of monitor.
Next, connect RS-232C cross cable to the first monitor’s RS-232C OUTPUT terminal and to second
monitor’s RS-232C INPUT terminal. Connect in the same way to the third and subsequent monitors.
Up to about 20 monitors can be connected, depending on the length of RS-232C cables and
installation environment.
Communication conditions
■
Set the RS-232C communication settings on the PC to match the monitor’s communication settings.
Baud rate:
9,600 bps
Data length:
8 bits
Parity bit:
None
Stop bit:
1 bit
Flow control:
None
"
Rear view
"
PC
RS-232C cross cable
To RS-232C
INPUT terminal
To COM port
"
First monitor
"
Second monitor
"
PC
RS-232C
cross cable
RS-232C
cross cable
To RS-232C
INPUT terminal
To COM port
To RS-232C
INPUT terminal
To RS-232C
OUTPUT terminal
To RS-232C
OUTPUT terminal
2
Daisy chain connection from a single PC.......
Advanced operation
1
One-to-one connection with a PC .......
Basic operation