49
B Upgrade Prompt
When upgrading, the TV set will light panel according to the panel parameter, and display the
progress bar. If the panel parameter of board matches the panel, you will see the following
image:
100% indicates the upgrade finished, and TV will auto reboot after user menu upgrading fin-
ished.
C Upgrade Flashing Status
You can judge the upgrade progress by flashing of the remote control LED light:
Upgrading:
Red 1000ms Green 1000ms alternates,the TV set will turn to Upgrade succeed or Upgrade Failed
status after the upgrading process.
Main program upgrade succeed:
Red 250ms Green 250ms alternates, flashing before power off.
Main program upgrade Failed:
Red 1750ms Green 250ms alternates, flashing before power off.
Notes
: In the upgrade process, as timer software is used to control flashing, situations such
as LED light stuck when creating partition of flash, is normal phenomenon.
6.4 Power On Upgrading
Copy the SW to a USB disk, link it to the USB port, Re-power on,
if the LED blinks continually,
it means the upgrading is on process, while the LED light off means the upgrading has been
completed.
Summary of Contents for LC-49CFE4041E
Page 1: ...1 SERVICE MANUAL models LC 48CFE4042E LC 49CFE4041E LC 49CFE4042E LC 49CFG4042E ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 32: ...32 3 14 PCB layout of Power board PW 168W2 801 for model LC 49CFG4042E ...
Page 33: ...33 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 38: ...38 4 EXPLODED VIEW 48 inch model 49 inch model LC 48CFE4042E LC 49CFE4041E LC 49CFE4042E ...
Page 39: ...39 49 inch model LC 49CFG4042E ...
Page 51: ...51 B Install USB driver Note Make sure the USB ISP tool is connected to PC before setup ...
Page 52: ...52 ...
Page 53: ...53 Select 仍然继续 to continue installation ...
Page 56: ...56 Click Read to select SW Click Auto and Run to start the upgrade ...
Page 57: ...57 Upgraded successfully ...