background image

Free standing type

AIR PURIFIER

OPERATION MANUAL

R

FP-JA30M

“Plasmacluster” and “Device of a cluster of grapes” are 

trademarks of Sharp Corporation.

*The number in this technology mark indicates an 

approximate number of ions supplied into air of 1 cm

3

which is measured around the center of a room with 

the “high-density plasmacluster 7000” applicable floor 

area (at 1.2 m height above the floor) at the medium 

wind volume in air purifying mode, when an air purifier 

using the high-density plasmacluster ion evolving 

device is placed close to a wall. This product is 

equipped with a device corresponding to this capacity.

FP-JA30M.indd   1

FP-JA30M.indd   1

2021/05/12   13:08:01

2021/05/12   13:08:01

Summary of Contents for FP-JA30M

Page 1: ... 1 cm3 which is measured around the center of a room with the high density plasmacluster 7000 applicable floor area at 1 2 m height above the floor at the medium wind volume in air purifying mode when an air purifier using the high density plasmacluster ion evolving device is placed close to a wall This product is equipped with a device corresponding to this capacity FP JA30M indd 1 FP JA30M indd ...

Page 2: ...sorbs odors as they pass through the filter Some odors absorbed by the filter may break down over time resulting in additional odor Depending on the usage environment especially when the product is used in extreme environments significantly more severe than normal household use this odor may become strong in a shorter period than expected If the odor persists the filter should be replaced NOTE The...

Page 3: ...NANCE E 8 REPLACEMENT GUIDELINES E 9 TROUBLESHOOTING E 10 SPECIFICATIONS E 11 CONTENTS FEATURES Unique Combination of Air Treatment Technologies Filtration System Plasmacluster TRAPS DUST Pre filter traps dust and other large airborne particles REDUCES ODORS Deodorizing filter absorbs many common household odors REDUCES POLLEN MOLD HEPA filter traps 99 97 of particles as small as 0 3 microns FRESH...

Page 4: ...ved Service Center or similarly qualified person in order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity conditions such as a bathroom Be cautious when cleaning the unit Corrosive cleansers may damage the exterior Only a Sharp Authorized Service Center sho...

Page 5: ...come in contact with and restrict the air intake and or air outlet Avoid use in locations where the unit is exposed to condensation or drastic temperature changes Appropriate conditions are when room temperature is between 0 35 ºC Place on a stable surface with sufficient air circulation When placing the unit on a heavily carpeted area the unit may vibrate slightly Avoid locations where grease or ...

Page 6: ...lter 10 Deodorizing Filter 4 Replace Filter indicator Light orange 11 Back Panel Pre Filter 5 Plasmacluster Ion Indicator Light blue 12 Bottom Tabs 6 POWER ON OFF Button 13 Handle 7 ALLERGY Button indicator Light green Press 3 sec LIGHT ON OFF Button 14 Power Cord 15 Plug Shape of plug depends on country FRONT BACK 4 8 6 3 14 9 11 12 5 7 10 FP JA30M indd 4 FP JA30M indd 4 2021 05 12 13 08 10 2021 ...

Page 7: ...erly 4 Replace the Back Panel to the main unit FILTER INSTALLATION To maintain the quality of the filter it is installed in the main unit and packed in plastic bag Be sure to remove the filter from the plastic bag before using the unit Do not operate the unit without the filter Pull Be sure to remove the power plug from the wall outlet 3 Push Bottom Tabs Push FP JA30M indd 5 FP JA30M indd 5 2021 0...

Page 8: ... the unit will return to the prior operation mode It is possible to switch this mode to another while operating The Plasmacluster Ion cannnot be turned OFF NOTE FAN SPEED SLEEP The unit will operate very quietly with low fan speed Plasmacluster Ion Indicator goes off automatically Even though the indicator is off Plasmacluster Ion is dispersed into air unless Plasmacluster Ion is turned off by NOT...

Page 9: ...c OFF When the unit starts operation the operation starts in the previous mode it was operated in NOTE When Plasmacluster Ion is ON the Plasmacluster Ion Indicator Light will turn on blue ON OFF NOTE Flashing Lighting 4h 8h CANCEL OFF TIMER Select the time turning off the unit during operation The unit automatically stops once the selected time is reached 3 sec more 3 sec more 3 sec FP JA30M indd ...

Page 10: ...N 1 Add a small amount of kitchen detergent to water and soak for about 10 minutes 2 Rinse off the kitchen detergent with clean water 3 Completely dry the filter in a well ventilated area How to clean stubborn dirt NOTE Do not apply excessive pressure when scrubbing the Back Panel CAUTION Gently remove dust from the HEPA FILTER and Deodorizeing Filter with a vacuum cleaner attachment or similar to...

Page 11: ...HEPA Filter Do not wash and reuse the filter The filter life and replacement period are based on the condition of smoking 5 cigarettes per day and the dust collection power is reduced by half compared with that of new filter Filter life varies depending on the room environ ment usage and location of the unit We recommend to replace the filter more fre quently if the product is used in a condition ...

Page 12: ...f the SLEEP mode is selected The Plasmacluster Ion Indicator Light is turned off 3 seconds after the SLEEP mode is selected Check to see if the Plasmacluster Ion OFF is selected Press for 3 seconds to light On Check to see if the Light Control OFF is selected Press for 3 seconds to light On AUTO RESTART Even when the plug is unplugged or the breaker is thrown during operation the unit resumes at t...

Page 13: ...ain amount of dust particles can be removed in 30 minutes JEM1467 2 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room at a height of approximately 1 2 meters from the floor when the product is placed next to a wall and run at the MED operation position Standby Power In order to operate the electrical circuits while the power plug is inse...

Page 14: ...E 12 MEMO FP JA30M indd 12 FP JA30M indd 12 2021 05 12 13 10 10 2021 05 12 13 10 10 ...

Page 15: ...E 13 MEMO FP JA30M indd 13 FP JA30M indd 13 2021 05 12 13 10 10 2021 05 12 13 10 10 ...

Page 16: ...TINS B413KKRZ 21E 1 SHARP BUSINESS SYSTEMS INDIA PRIVATE LIMITED R FP JA30M indd 14 FP JA30M indd 14 2021 05 12 13 10 11 2021 05 12 13 10 11 ...

Reviews: