background image

10

11

WHAT YOU NEED TO KNOW\HOW TO OPERATE

CONTROL PANEL

EASY-TO-USE FUNCTIONS

HOW TO OPERATE

After you insert the power plug, all the LED indicators and digital display are on for 1 second and then turn 

off. Meanwhile, the buzzer sends three alert sounds. Each time you press a button, the buzzer sends a 

alert tone. When you press the ON/OFF button to power the unit off, the buzzer sends a long beep 

sound.

After you press the ON/OFF button to power the unit on and the buzzer sends a alert 
tone, the dehumidifier starts the continuous dehumidifying mode, the power indicator 
and continuous dehumidifying function indicator are turned on, and the dual-digit 
display shows the current humidity. Moreover, the unit automatically set the louver to 
the position of 85°.

After you press the ON/OFF button to power the unit off during operation of the 
dehumidifier, the dehumidifier will stop operation, and the louver will be closed 
automatically. Meanwhile, the buzzer sends out a long beep.

Press the MODE button. You can select among the four dehumidifying modes: 
LAUNDRY, COMFORT, CONTINUOUS and AUTO.

1. LAUNDRY: The laundry indicator is turned on, the compressor starts, and the fan 
runs at the highest speed to dry clothes. The dehumidifier will not stop until the water 
tank is full. 
[When you want to dry clothes]

2. COMFORT: The Comfort indicator is turned on, the dehumidifier dehumidifies while 
the compressor starts or stops so that the relative humidity is kept at comfortably 60%, 
and the fan rotates at the low speed.  
[When you want the dehumidifier to automatically control the humidity so that the 
relative humidity is fixed at the comfortable value.]

3. CONTINUOUS: The Continuous indicator is turned on, the compressor starts, the 
fan rotates at the low speed, and the dehumidifier continues dehumidifying until the 
water tank is full.
[When you want to always keep dry]

AUTO DEFROST

 

During defrosting, the defrosting indicator is on, the compressor stops, and the fan keeps rotating at the 
highest speed. After the defrosting ends, the dehumidifying function starts, the compressor restarts, and the 
fan resumes the preset speed.

When the temperature sensor fixed on the copper pipe of evaporator detects that the dehumidifier temperature 
is lower than or equal to -1°C (and the relative room temperature is lower than or equal to 13°C), the 
dehumidifier will start the automatic defrosting procedure, namely, the dehumidifier defrosts automatically after 
the dehumidifying mode runs for 20 minutes; when the evaporator surface is defrosted completely, the 
temperature sensor detects that the temperature is higher than or equal to 2°C and the defrosting duration is 
longer than or equal to 10 minutes, the dehumidifier will stop defrosting and enable the dehumidifying function.

 

COMPRESSOR STOP/START PROTECTION

 

During operation, if the compressor stops due to any operation, the dehumidifier will automatically switch to 
the function of restarting the compressor after stopping it for 3 minutes, namely, the compressor cannot be 
restarted in 3 minutes, but other functions are available.

In the dehumidifying mode, if you remove and replace the water tank or power off and power back on the 
dehumidifier, the dehumidifying function will start after an interval of 3 minutes.

 

8IFOUIFEFIVNJEJGJFSPQFSBUFTBUBMPXUFNQFSBUVSFUIFFWBQPSBUPSTVSGBDFNBZCFGSPTUFE5P
FOTVSFOPSNBMPQFSBUJPOUIFEFIVNJEJGJFSQSPWJEFTUIFBVUPNBUJDEFGSPTUJOHGVODUJPO

Summary of Contents for DW-D12A

Page 1: ...G FOR A LONG PERIOD OF TIME SPECIFICATIONS TROUBLESHOOTING DEHUMIDIFIER OPERATION MANUAL Model Do not use the product for commercial purposes High Density 7 000 The number in this technology mark refers to the approximate quantity of ions per cm3 of air released from the dehumidifier equipped with a high concentration Plasmacluster ion generating unit which was measured at the center point 1 2 met...

Page 2: ...l open position 2 FEATURES SAFETY PRECAUTIONS 3 SAFETY PRECAUTIONS Do not connect the unit from extension cord or multiple wiring with other electronic appliances Otherwise electric shock fire or overheat may be caused Do not damage the power cord Do not process forcibly bend pull by force twist or bind the power cord Do not place heavy objects on the power cord or apply too much force to it Do no...

Page 3: ...ing or feeding Otherwise health problems may be caused Do not use for storage special purpose for artworks or academic materials Otherwise quality degradation of stored materials may be caused Main Unit Do not make modifications Disassembly repairing modifications shall not be made by a person other than the service engineer Otherwise fire electric shock or injury may be caused Do not place spray ...

Page 4: ... only on level stable surfaces If water leaks from the dehumidifier and soaks the furniture in the room electric shock electric leakage or fire may be caused Always have plenty of room around the main unit Poor ventilation may cause over heating fire malfunction Be sure to clean the product floor and surroundings when using the product in a same place for a long period of time Move the dehumidifie...

Page 5: ... places with direct sunlight Level stable place May cause deformation or safety device activation If there is a noise in TV semiconductor or radio clock does not display the correct time move the product away as far as possible Thick carpet or futon is a very unstable place Upper 50cm or more Behind 20cm or more Front 50cm or more Sides 20cm or more Operate it in a room with temperature from 5 C t...

Page 6: ...xed at the comfortable value 3 CONTINUOUS The Continuous indicator is turned on the compressor starts the fan rotates at the low speed and the dehumidifier continues dehumidifying until the water tank is full When you want to always keep dry AUTO DEFROST During defrosting the defrosting indicator is on the compressor stops and the fan keeps rotating at the highest speed After the defrosting ends t...

Page 7: ... will stop running and enable the over temperature protection function All the indicators turn off only the digital display blinks and shows C2 none of the buttons work and the buzzer does not beeps In this case you must power off and back on the dehumidifier When you press the MODE button to set the Auto mode you can press the HUMIDITY SELECTION AUTO MODE button to cycle among 60 RH 70 RH 80 RH 4...

Page 8: ... the floor No part of the drainpipe can be folded or upturned and the outlet of the drainpipe cannot go deep under the liquid surface of another container otherwise water cannot be drained smoothly or drainage may stop Continuous drainage NOTE Always stop the operation and dispose water before moving the main unit Water in the tank may spill and damage household goods Clean the inside of water tan...

Page 9: ...o the main unit 3 1 Insert the two hasps of the filter into the holes on the main unit 2 The filter installation completes when the fastener is clamped in the main unit We recommend periodical cleaning for a long clean and sanitary use Dry the tank with soft cloth Install the water tank cover WATER TANK Remove the water tank cover Wash the inside of the tank Clean it with a white tableware cloth A...

Page 10: ...sunlight and keep the dehumidifier at a place with good ventilation Place the dehumidifier in the supplied carton or cover it with a dustproof hood such as a plastic bag for storage If the dehumidifier is not covered dust may enter the main unit and will be blown out when the dehumidifier operates next time Keep the main unit upright during storage Do not lay it horizontally or invert it 2 1 3 4 F...

Page 11: ... C the unit will operate according to the preset mode where the transition phase is 30 C to 32 C When the humidity setting button is not pressed during operation of the unit the dual digital display shows the ambient humidity value 30 35 40 85 90 of the unit LO is displayed when the humidity value is lower than 30 RH HI is displayed when the humidity value is higher than 90 RH The air volume incre...

Page 12: ...操作 保護功能啟動 操作方法 操作面板 方便的功能 其他功能 水滿自動停機功能 自動復原記憶功能 保護功能 排水方法 儲水箱 連續排水 保養 吸入口 污垢嚴重時 儲水箱 主機 長期不使用時 規格 故障時的檢查事項 抽濕機 本產品請勿用於商業用途 本技術所採用的數字是將內置了高濃度PCI產生器的抽濕機放 在牆角 在乾衣除濕模式下 將自動擺風設置為啟動時 在高 濃度PCI 7000適用的房間 溫度28 濕度50 的中央附近 距 離地面1 2米 測出的每立方厘米空氣中所含Plasmacluster Ion 的估計值 此標誌及 Plasmacluster 都是SHARP 株式會社的註冊商標 High Density 7 000 DW D12A ...

Page 13: ...共同使用一個插座 否則可能會導致觸電 發熱 火災 請勿使電源線破損 請勿對電源線進行任意更換 加工 強制彎曲 拉扯 扭曲 束紮等 請勿對其承載重物或夾壓 請勿擅自更換電源線 移動時 請避免腳輪對電源線造成損害 電源線破損是引起火災 觸電的原因 不可使用額定電壓 220V 50Hz 之外的電源 請勿以直接插入或拔出電源插頭的方法來代替正常的主機開關 否則可能是引起火災 觸電的原因 異常情況 如有燒焦味等 或故障時 應立即停止運行 並拔出電源插頭 確認電源插頭上沒有積塵及沒有鬆動後 將其牢固地插入電源插座 及應定期用乾布擦拭電源 插頭上的灰塵 若有灰塵附著或插頭鬆脫可能是引起觸電或火災的原因 主機 不可作任何改裝 禁止非維修技術人員分拆 改造 維修主機 否則可能是引起火災 觸電 受傷的原因 請勿將噴霧器等的罐子放在主機的附近 另外 請勿在主機附近使用類似易燃的危險物品 汽油 稀釋劑 否則可能是...

Page 14: ...氣體的地方 否則可能是引起觸電或過熱 漏電 火災的原 因 在出風口或風能到達的地方請勿放置燃燒器具 否則可能是引起燃燒器具不完全燃燒的原因 請勿站在或依靠在主機上 由於移動或翻倒 可能是造成受傷的原因 請勿把除濕用的水用作飲料或飼養寵物 可能會對健康帶來損害 請勿用於美術品或學術資料等的保存 特殊用途 否則可能是引起保存品品質底下的原因 移動時請務必停止運行 並倒掉儲水箱內的 水 請放在堅固平穩的地方使用 除濕機內部的水若漏在室內 導致家具浸 濕 可能是引起觸電 漏電 火災的原因 主機的周圍請保持下圖所示的尺寸空間 通風不良 可能是引起發熱 起火 故障 保護裝置動作的原因 在同一位置長期使用的情況下 在產品的下 部和地面周圍可能會有污垢 請予以注意 移動產品 定期地對地面進行清掃 請勿在機器運行時取下水箱 以免水滴灑在地面或地毯上 除非得到監護人或負責其安全人士的適當監 督或指導 否則 此...

Page 15: ...果本機在除濕運行時 取出水箱後再放回或關機後再開機 期間時間間隔需達3分鐘 其除濕功能才會啟動 把手 對於容易造成破損的地面 凹凸不平的地方 毯毛較長的地毯等 請提起主機移動 不然可能是 導致地面或地毯等的表面破損的原因 1 2 電源為 220V 注意 與左右距離 大於 20厘米 與後方距離 大於 20厘米 與前方距離 大於 50厘米 與上方距離 大於 50厘米 包裝材料 請務必手握把手將主機從包裝 箱內取出 將電源插頭插 入插座 將主機從包裝 箱內取出 放置在堅固平 穩的地方 插入並接通電源後會發出三聲 嘩嘩嘩 警鳴聲 屬正常現象 海濱地區等 鹽份較多的地方 溫泉地區等硫化氣體較多的地方 機械油較多的地方 油煙較多的地方 在下列地方請勿使用 dž 請勿在除濕機附近使用氟化乙烯樹脂或含矽酮配方的化妝品等dž 請在約5 C 35 C的房間內使用 安裝位置要求 否則 可能導致外殼脫色 變形 安全 ...

Page 16: ...後停止 當您希望持續保持乾爽時 4 AUTO 自動除濕 自動除濕指示燈亮起 本機會按照設定的濕度進行除濕 可以按HUMIDITY SELECTION 濕度設定 鍵對希望達到的濕度進行設定 設定順序 為 60 RH 預設 70 RH 80 RH 40 RH 50 RH 60 RH 循環 當您需要設定特定濕度進行除濕時 在任何情況下按下HUMIDITY SELECTION 濕度設定 鍵 都會跳到自動除濕模式 自動除濕指示燈亮起 當按下MODE 模式轉換 鍵設定自動除濕功能時 可按HUMIDITY SELECTION 濕 度設定 鍵設定濕度 60 RH 預設 70 RH 80 RH 40 RH 50 RH 60 RH 循環 當按MODE 模式轉換 鍵至LANUDRY 乾衣除濕 或COMFORT 舒適除濕 或 CONTINUOUS 連續除濕 時 再按HUMIDITY SELECTION 濕度設定 ...

Page 17: ...話可能會滋生細菌 發出異味 取出儲水箱後 水滿指示燈閃爍 操作停止 1 2 3 排水孔塞頭 連續排水管 其他功能 水滿自動停機功能 當本機在除濕運行時 若水箱水滿達到設定高度 壓縮機 風扇會停止運作 同時提示音將會響起十聲 主機 停止操作 水滿指示燈點亮 自動復原記憶功能 按ON OFF鍵處於關機後 再重新按ON OFF鍵開機 將會以關機前的操作模式運行 本機在操作時斷電 即拔掉電源插頭 再重新接電後將會以斷電前的操作模式運行 保護功能 為避免本機在非正常環境下運行而產生危險 當進風口的溫濕度感測器檢測到當前的環境溫度低於或等於 0 或高於或等於40 主機會停止運行並啟動保護功能 提示音一直發出三長兩短的警示聲 所有燈號 熄滅 只有顯示屏幕顯示C1 當蒸發器上的溫度感測器檢測到其溫度連續2分鐘內高於或等於40 本機將停止運行並啟動保護功能 所有 燈號熄滅 只有顯示屏幕顯示C2 此時按任何按...

Page 18: ...掉儲水箱的水以後 再取 下水箱蓋 從這邊慢慢打開 請勿取下白色發泡材料 使儲水箱蓋插入外部溝槽中 否則可能導致漏水 保 養 1 2 3 4 保養 吸入口 污垢嚴重時 灰塵用吸塵器吸取 吸入口面蓋的堵塞 會導致除 濕能力下降和浪費電量 吸入口面蓋若不蓋上進行運行 的話 會導致主機內部積塵而 發生故障 將插頭從插座上拔出 為安全起見 請務必停止運行 並將插頭從插座上拔出 取下過濾網 每週一次 1 為了能夠清潔衛生地長期使用 請進行 定期保養 按原樣重新安裝在 主機上 3 1 過濾網兩個搭扣插入主機孔 2 卡扣卡入主機體即完成安裝 吸塵器 浸洗過濾網並晾乾 使用牙刷等輕輕去除灰塵 污垢嚴重時 請使用已稀釋的中性清潔 劑 食物器皿專用清潔劑 配合溫水清洗 2 ...

Page 19: ...磨粉 鹼性清潔劑 熱水 酸等 用沾上溫水 35 以下 或者中性清潔劑 食物器皿專用清潔劑 的柔軟的布把污垢擦掉 腳輪4個 清掃吸入口 請將電源插頭拔掉 把儲水箱內的水全部 倒掉 風乾2天以保 持乾燥 排水口 取下儲水箱蓋 把儲水箱內的 水擦拭乾淨 吸入口 吸塵器 避免陽光直射 存放在通風的地方 存放在附帶的紙箱裡或蓋上防塵 的罩子 塑料袋等 加以保存 如不遮蓋保存 灰塵可能進入主 機 在下次運行時可能會有灰塵 吹出 存放時請將本機垂直擺放 切勿 橫放或倒轉 2 1 3 4 15 注意 DW D12A 220V 240V 50Hz 12公升 日 6 5公升 日 160瓦 0 45W 13 26平方米 約4公升 約1 8米 314毫米 闊 x225毫米 深 x527毫米 高 約10公斤 30 80 RH 26 7 60 RH 26 7 60 RH 型 號 電 源 抽 濕 能 力 耗 電 量 備...

Page 20: ... 8 聲 音 插上電源 會響起 嗶嗶嗶 三聲提示音 每按一次按鍵 提示音 響起一聲 按 開 關 鍵關機 提示音長響一聲 咻嚅咻嚅 GO GO 製冷劑的循環聲音 嘰 喔 喔 壓縮機的運行聲音 運 行 停 止 故 障 時 的 檢 查 事 項 主機是否有傾斜 翻倒 跌落的情況 請不要放在有震動的地方 請放在平穩的地方使用 室溫較低的時候開始運行的話 在開始的數秒鐘內有時候會發生聲 音變大的情況 根據溫度變化 時間也會有所變化 抽濕機有晃動嗎 地面是不是平整 請不要放在有震動的地方 請放在平穩的地方使用 吸入口面蓋堵塞了嗎 請打掃 嗶嗶 滿水指示燈 7 6 6 10 12 6 10 漏水 當環境溫度在32 以上時 為降低主機內部溫度 即使機器正在低 風量的操作模式運行 風量也會自動增強至高風量運行 當環境溫度低於30 時 會按照原設置模式運行 30 32 之間 則是一個過度階段 主機運行時 在未有...

Reviews: