LH75400/01/10/11 (Preliminary) User’s Guide
Controller Area Network
6/17/03
22-21
22.3.2.11 Receive Error Counter Register
RXERR is the Receive Error Counter Register. The RXERR Register records the current
value of the Receive Error Counter. After a System Reset or when a Bus Off event occurs,
this register is automatically set to ‘0’. This register works with the Transmit Error Counter
(described in Section 22.3.2.12) to create a metric for communication quality based on his-
toric performance.
This register can only be written to in Reset Mode. Changes made during Reset Mode only
go into effect when the CAN Controller returns to Operating Mode.
In Operating Mode, this register is Read Only. Writing to this register has no effect when
the CAN Controller is in Bus Off state.
Table 22-25. RXERR Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
RXERR
.7
RXERR
.6
RXERR
.5
RXERR
.4
RXERR
.3
RXERR
.2
RXERR
.1
RXERR
.0
RESET
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
ADDR
0xFF 0x38
Table 22-26. RXERR Register Definitions
BIT
NAME
DESCRIPTION
31:8
///
Reserved
Writing to these bits has no effect. Reading returns 0.
7:0
RXERR 7 - RXERR.0
Receive Error Counter Value