(Error message)
F9
0
Content
ICU-PRT communication trouble
Detail
Cause
SCSI LSI abnormality
ICU PWB defect
SCSI connector connection defect
Printer PWB defect
Check and remedy
Replace the printer PWB.
Check the SCSI connector.
Replace the printer PWB.
Replace the ICU PWB.
F9
01
Content
PRT DRAM trouble
Detail
DRAM trouble in the option printer board. (When operating the scanner mode)
Cause
DRAM module is broken and access cannot be made.
DRAm module installation trouble
Check and remedy
Check with SIM 57-1.
F9
02
Content
PRT Centro port check error
Detail
Option printer board Centro port trouble
Cause
Centro port defect
Printer PWB defect
Check and remedy
Replace the printer board.
F9
03
Content
Network card trouble.
Detail
Network card self test trouble.
Cause
Network card defecft.
Printer PWB defect.
Network card connector connection defect.
Check and remedy
Check the Network card connector.
Replace the printer PWB.
Replace the Network card.
F9
04
Content
Printer program error.
Detail
Program data trouble in the option printer board.
Cause
Flash memory data is destroied.
Check and remedy
Replace or rewrite the Flash memory.
Replace the printer PWB.
F9
05
Content
Short of memory capacity on the ICU PWB
Detail
Total memory is less than 16MB on the ICU PWB.
Cause
Memory defect
SIMM memory connector connection defect
ICU PWB defect
Wrong type SIMM memory is installed
Check and remedy
Replace the ICU PWB
Replace the memory
Check the memory connector
F9
10
Content
PRT SCSI LSI abnormality
Detail
An error occurred in SCSI communication with the option printer board.
Cause
SCSI LSI abnormality
ICU PWB defect
Printer PWB defect
SCSI connector connection defect
Check and remedy
Replace the printer PWB.
Check the SCSI connector.
Replace the printer PWB.
Replace the ICU PWB.
F9
90
Content
ICU-PRT communication trouble (PRT detection)
Detail
Cause
SCSI LSI abnormality
ICU PWB defect
SCSI connector connection defect
Printer PWB defect
Check and remedy
Replace the printer PWB.
Check the SCSI connector.
Replace the printer PWB.
Replace the ICU PWB.