AR-M550/M620/M700 EXTERNAL VIEW AND INTERNAL STRUCTURE 5 - 19
J. Adjustment volume
23
F1,F2
Fuse
Time lag
240V 10A
AC power source overcurrent protection (Main
source)
AC power
PWB EX200
EX Japan
200V system
24
F3,F4
Fuse
Time lag
250V 2.0A
Thermal heater overcurrent protection
AC power
PWB EX200
EX Japan
200V system
25
F5
Fuse
Time lag
250V 2.5A
MSW detection circuit overcurrent protection
AC power
PWB EX200
EX Japan
200V system
26
HLTS1
Thermostat
120VAC 15A
240VAC 10A
Fusing roller overheat protection
Fusing unit
Japan
27
HLTS2
Thermostat
120VAC 15A
240VAC 10A
Fusing roller overheat protection
Fusing unit
Japan
28
HLTS3
Thermostat
120VAC 15A
240VAC 10A
Sub heat roller overheat protection
Fusing unit
Japan
29
HLTS1
Thermostat
120VAC 15A
240VAC 10A
Fusing roller overheat protection
Fusing unit
EX Japan
30
HLTS2
Thermostat
120VAC 15A
240VAC 10A
Fusing roller overheat protection
Fusing unit
EX Japan
31
HLTS3
Thermostat
120VAC 15A
240VAC 10A
Sub heat roller overheat protection
Fusing unit
EX Japan
Name
Function/Operation
MODEL
NOTE
RV102
DC sub power unit +12V power output voltage adjustment VR
RV201
DC main power unit +38V power output voltage adjustment VR
RV202
DC main power unit +24V power output voltage adjustment VR