LC-40/46/52/60LE810UN (1st Edition)
6 – 15
Table 1. Concrete flashing pattern
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing impossible).
3. New method
Item
Outline display
Detail display
Cause
Slow flashing
Fast flashing
Slow flashing
Fast flashing
Inverter/Lamp sys-
tem failure
Flashes once
None
Flashes once
Flashes once
Lamp error
Power PWB
failure
(Power failure, etc.)
Flashes twice
None
Flashes twice
Flashes once
Power supply error 1 (*2) AC_DET error
Flashes twice
Power supply error 2 (*2) UR+13V error
Flashes 3 times Power supply error 3 (*2) D3.3V error
Flashes 5 times Panel power supply error
Main PWB
failure
(Communication
failure, etc.)
Flashes 3 times
None
Flashes 3 times
Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times Regular communication error
Flashes 5 times Other communication error
Others
Flashes 4 times
None
Flashes 4 times
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times Notification from the main microcomputer (*3)
VerUP executing
Flashes smoothly
None
—
—
Version upgrading
VerUP succeeded
Flashes in a stair-
case pattern
None
—
—
Version upgrade succeeded
VerUP failed
None
Flashes continu-
ously
—
—
Version upgrade failed
ROM data failure
None
Flashes continu-
ously
—
—
Start-up after failing version upgrade (*4)
Error flashing
Center icon
Press the [MENU] key on the remote control.
Center icon
Center icon
Center icon
Flashing during Verup
Flashing when completing Verup
400ms
1600ms
400ms
300ms
1600ms
100ms
500ms
500ms
1000ms
400ms
400ms
1600ms
1000ms
1000ms
1000ms
Note: The North American models have no flashing
pattern of slow flashing only. The detail display
is presented by combining slow flashing