LC-40/46/52/60LE810UN (1st Edition)
5 – 8
6. Special features
* STANDBY CAUSE (Page 1/24)
Display of a cause (code) of the last standby
The cause of the last standby is recorded in EEPROM whenever possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
* EEP SAVE (Page 24/24)
Storage of EEP adjustment value
* EEP RECOVER (Page 24/24)
Retrieval of EEP adjustment value from storage area
23
1
ERROR STANDBY CAUSE1
2
ERROR STANDBY CAUSE2
3
ERROR STANDBY CAUSE3
4
ERROR STANDBY CAUSE4
5
ERROR STANDBY CAUSE5
6
ERROR STANDBY CAUSE RESET
24
1
EEP SAVE
Writing setting values to EEPROM
2
EEP RECOVER
Reading setting values from EEPROM
3
MODL NAME
4
PANEL SIZE
5
SETTING FOR ADJ
6
PANEL LIMIT
7
PANEL RANGE LIMIT
8
SHORT CHECK MODE
9
SHORT CHECK CURRENT
10
CURRENT SW
*1 Details of P1.9 (NORMAL STANDBY CAUSE)
2
No operation off
in the cause of “no operation off”
3
No signal off
in the cause of “no signal off”
4
PC power management mode 1
in the cause of “Standby mode MODE1”
5
PC power management mode 2
in the cause of “Standby mode MODE2”
6
Off timer
in the cause of “SLEEP timer”
8
Command from RS232C
in the cause of command by RS-232C
*2 Details of P1.10 (ERROR STANDBY CAUSE)
11
Prolonged unspecified-signal input in PC mode
in the cause of continuous “out of range”, PC input mode
17
Temperature error
in the cause of abnormal temperature
1A
Monitor trouble detected
in the cause of abnormal monitor mode
22
LCD controller Rom error
in the cause of software abnormality of LCD controller
Page Line
Item
Description
Remarks (adjustment detail, etc.)