11
Setup
Entering SETUP MENU
Connect AN-LS1 to a computer using RS-232C or Telnet, and open the “SETUP MENU” on the computer
to carry out various settings for AN-LS1.
When Connecting Using RS-232C
1
Launch general purpose terminal emulator.
2
Set settings for the RS-232C port of the terminal emulator as follows.
Baud Rate
: *9600 bps
Data Length
: 8 bit
Parity Bit
: None
Stop Bit
: 1 bit
Flow Control
: None
* This is the default value. If the value of Baud Rate for AN-LS1 has been changed, set Baud Rate
here according to the changed value on AN-LS1. (
3
Connect the plug for the AC adapter to a wall outlet to supply the power while holding
down the “A” (or “a”) key on the terminal keyboard.
4
Keep holding down the “A” (or “a”) key for more than 3 seconds. “Setup Menu Enable”
will be displayed.
5
Press the return key on the terminal keyboard.
6
Input “setup” and press the return key.
7
“User Name:” is displayed. Input the user name and press the return key.
(If a user name has not yet been set, just press the return key.)
8
“Password:” is displayed. Input the password and press the return key.
(If a password has not yet been set, just press the return key.)
9
Input “setup” and press the return key.
|
SETUP MENU will be displayed.
S E T U P M E N U
[1]IP Address
[2]Subnet Mask [3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Unit Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
•
User name and password are not set in the initial settings.
•
If the user name or password is entered incorrectly three times, SETUP MENU will be quit.
http://www.usersmanualguide.com/