Mounting the indoor unit
For right side piping
(1) Pass the pipes and the drain hose through the
piping hole.
(2) Hook the unit onto the mounting plate.
(3) Pull the connecting cable into the indoor unit.
(4) Push the unit and apply the bottom hooks to the
mounting plate's support.
(5) Pull the bottom of the unit to check that the unit
For left side piping
(1) Reverse the positions of the drain hose and
drain cap. Refer to “
Exchange the drain hose
”.
(2) Connect the pipes and wrap tape around the in-
sulation of the piping joints tightly not to become
thick.
(3) Bind the pipes and connecting cable with tape.
(4) Set the pipes and connecting cable along the
back of the unit, and attach the piping holder.
(5) Pass the pipes, connecting cable and the drain
hose through the piping hole.
(6) Hook the unit onto the mounting plate.
(7) Push the unit and apply the bottom hooks to the
mounting plate's support.
(8) Pull the bottom of the unit to check that the unit
Notes:
•
Bend the pipes carefully as not to damage them.
•
Lay the drain hose below the pipes.
(1) Remove the screw and pull out the drain
hose.
(2) Pull out the drain cap.
(3) Reconnect the drain hose to the right
and insert the drain cap to the left.
•
Fully insert the drain hose until it stops and
•
Insert a hexagon wrench (4 mm diagonal)
into the drain cap, and press it fully.
Caution:
After replacing, make sure that both the drain
ITEMS
Q’ty
APPLICATION
ITEMS
Q’ty
APPLICATION
ITEMS
Q’ty
APPLICATION
1
MOUNTING PLATE
1
To mount the indoor
unit on the wall.
4
DRY BATTERY
2
For the remote con-
trol.
AAA batteries.
6
REMOTE CONTROL
HOLDER
1
To mount the remote
control on the wall.
2
LONG SCREW
(M4.5x30)
7 plate with the wall
plugs.
5
SHORT SCREW
(M4x20)
2
REMOTE
CONTROL HOLD-
ER.
7
CABLE COVER
1
To secure the cable.
3
REMOTE CON-
TROL
1
To control remotely.
1 COVER
8
MANUALS
1 Installation manual
1 Operation manual
INSTALLATION DIAGRAM
Drain Hose
MOUNTING PLATE
Taping
NOTES ON LOCATIONS
Provide as much installation space as possible for
Drain Cap
ACCESSORIES
SAFETY PRECAUTIONS
•
Installation must be made in accordance with the installation
manual by
service personnel.
•
Be sure to use the attached accessories parts and
parts
for installation.
falling.
•
The appliance shall be installed in accordance with national wir-
ing regulations.
•
After installation has complete, check that there is no leakage of
refrigerant gas.
•
Ventilate the room if refrigerant gas leaks during installation.
•
Use the
electrical cable.
Make sure the cable is secured in place and that the terminals are free
result.
•
Form the cable so that the control box cover, the cord holder and
cable holder are not loose.
OPER
INSTALL
Drain Hose
Hexagon wrench
Drain cap
Drain Hose
Screw
Drain Cap
1.
entire room.
2. Make a drain hose hole for easy drainage.
3.
both sides and above the unit.
4.
5. Keep TV set, radio and the like 1 m or more away from the unit and the remote
control.
6. Keep the air inlet clear of obstacles that could block incoming air.
7. The remote control may not function properly in a room equipped with an electronic
lighting.
8. Select a location that does not cause loud operation noise and extreme vibrations.
2 SETTING UP THE INDOOR UNIT
Piping route
zone
without leaving any sharp edge.
(Keep the cut-out plate for possible future use.)
Plate
Cut the plate along
notch.
Plate
Plate
Hook
MOUNTING PLATE
SPLIT TYPE ROOM AIR CONDITIONER
INSTALLATION MANUAL
B510
AH-XPC9RV
AH-XPC12RV
ENGLISH
•
Tighten the
nut with a torque wrench according to the
method.
long time and cause refrigerant gas leakage.
•
When installing the unit, take care not to enter air substance other
than the
refrigerant(R410A) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
•
Be sure to connect the refrigerant pipe before running the compres-
sor.
Otherwise, it will cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
•
Earth the unit.
Incomplete earth may cause electrical shock.
•
Install an earth leakage breaker to avoid electric shock in case of
leak.
Use the current-activated, high-sensitivity, high-speed type breaker with a
rated sensitivity current of below 30 mA and an operating time of below 0.1
second.
•
Arrange the drain hose to ensure smooth drainage.
•
This room air conditioner uses refrigerant R410A.
Use the
.
Carefully read and follow these instructions for
smooth and trouble-free installation.
Screw
Tape
Insulation
Piping holder
Use the refrigerant pipes shown in the table below.
Pipe size
Pipe
thickness
Thermal insulation
Liquid
side
1/4"
(ø 6.35 mm)
0.8 mm
Thickness:
6 mm or thicker
Material:
Polyethylene foam
Gas
side
3/8"
(ø 9.52 mm)
•
The thermal insulation should cover both the gas and liquid
pipes.
Exchange the drain hose
1
2
3
4
5
This manual describes the installation of indoor unit only
For the installation of the outdoor unit, see the installation manual accompanying outdoor unit.
Wall
1 PLACING THE MOUNTING PLATE AND MAKING A PIPING HOLE
Installing the mounting plate
(1) Referring to the “
INSTALLATION
DIMENSION OF INDOOR UNIT”
,
holes and the piping hole.
marked in circle around the hole.
(7 points)
• Make sure that the mounting
plate is horizontally.
(2) Secure the mounting plate to the
wall with the long screws and
check the stiffness.
1
MOUNTING PLATE
2
LONG SCREW
Indoor
Outdoor
Cut with a saw.
Cap
5 mm
Sleeve (Downward to
outdoor)
Length unit: mm
Center of wall hole
Center of wall hole
Outline of indoor unit
(unit size)
(unit size)
INSTALLATION DIMENSION OF INDOOR UNIT
Making a piping hole
(1) Drill a piping hole
with 70mm diameter
concrete drill or a hole
saw with a 5mm down
ward slant to the out-
side.
(2) Set the sleeve and
caps.
Tape
Pipes
Drain Hose
50 mm or more
50 mm or more
50 mm or more
70 mm or more
Coating tape