2
32C240
32C241
IMPORTANT SERVICE SAFETY PRECAUTION
Ë
Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and the servicing guidelines which follow:
CAUTION: FOR CONTINUED
PROTECTION AGAINST A
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE 4A-
125V FUSE.
X-RADIATION AND HIGH VOLTAGE LIMITS
1. Be sure all service personnel are aware of the
procedures and instructions covering X-radiation. The
only potential source of X-ray in current solid state
TV receivers is the picture tube. However, the picture
tube does not emit measurable X-Ray radiation, if
the high voltage is as specified in the "High Voltage
Check" instructions.
It is only when high voltage is excessive that X-
radiation is capable of penetrating the shell of the
picture tube including the lead in the glass material.
The important precaution is to keep the high voltage
below the maximum level specified.
2. It is essential that servicemen have available at all
times an accurate high voltage meter.
The calibration of this meter should be checked
periodically.
3. High voltage should always be kept at the rated value
−
no higher. Operation at higher voltages may cause
a failure of the picture tube or high voltage circuitry
and;also, under certain conditions, may produce
radiation in exceeding of desirable levels.
4. When the high voltage regulator is operating properly
there is no possibility of an X-radiation problem. Every
time a color chassis is serviced, the brightness should
be tested while monitoring the high voltage with a
meter to be certain that the high voltage does not
exceed the specified value and that it is regulating
correctly.
5. Do not use a picture tube other than that specified or
make unrecommended circuit modifications to the
high voltage circuitry.
6. When trouble shooting and taking test measurements
on a receiver with excessive high voltage, avoid being
unnecessarily close to the receiver.
Do not operate the receiver longer than is necessary
to locate the cause of excessive voltage.
WARNING
1. For continued safety, no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
3. Semiconductor heat sinks are potential shock hazards
when the chassis is operating.
4. The chassis in this receiver has two ground systems
which are separated by insulating material. The non-
isolated (hot) ground system is for the B+ voltage
regulator circuit. The isolated ground system is for
the low B+ DC voltages and the secondary circuit of
the high voltage transformer.
To prevent electrical shock use an isolation
transformer between the line cord and power
receptacle, when servicing this chassis.
SERVICING OF HIGH VOLTAGE SYSTEM
AND PICTURE TUBE
When servicing the high voltage system,
remove the static charge by connecting a
10k ohm resistor in series with an insulated
wire (such as a test probe) between the pic-
ture tube ground and the anode lead. (AC
line cord should be disconnected from AC
outlet.)
1. Picture tube in this receiver employs integral
implosion protection.
2. Replace with tube of the same type number for
continued safety.
3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing
shatterproof goggles and after discharging the high
voltage anode completely.
4A 125V
Summary of Contents for 32C240
Page 12: ...6 5 4 3 2 1 A B C D E F G H 12 32C240 32C241 CHASSIS LAYOUT ...
Page 13: ...6 5 4 3 2 1 A B C D E F G H 13 32C240 32C241 BLOCK DIAGRAM ...
Page 15: ...6 5 4 3 2 1 A B C D E F G H 15 32C240 32C241 SCHEMATIC DIAGRAMS CRT UNIT ...
Page 16: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 16 32C240 32C241 MAIN 1 UNIT ...
Page 17: ...17 16 19 18 15 14 13 12 11 10 17 32C240 32C241 ...
Page 18: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 18 32C240 32C241 MAIN 2 UNIT ...
Page 19: ...17 16 19 18 15 14 13 12 11 10 19 32C240 32C241 ...
Page 20: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 20 32C240 32C241 2 LINE Y C UNIT ...
Page 21: ...17 16 19 18 15 14 13 12 11 10 21 32C240 32C241 ...
Page 23: ...6 5 4 3 2 1 A B C D E F G H 23 32C240 32C241 PWB A MAIN Unit B Side ...