21HF2-SS
5 – 1
21HF2-SS
Service Manual
CHAPTER 5.
TROUBLE SHOOTING FLOWCHART
[1] TROUBLE SHOOTING FLOWCHART
NO RASTER
Blown out.
Replace the fuse.
Check IC701, D701 and
C705.
The fuse is blown out again.
Does horizontal circuit
oscillate ?
Check T701 pin (17) voltage
(Approx. 310V at 220V AC)
Check F701.
Check Secondary Main+B
(Approx. 130V)
Check CRT connector K-
wire and the signal on it.
Check Q601 and Q602.
Check 185V
Bias on
CRT board.
Check
IC801.
Checking the
protector circuit.
Check Q752 for 8V regulator
circuit and Q751, Q754 for
5V regulator circuit.
Check D751, IC702, D750
and IC703.
Check R701.
Summary of Contents for 21HF2-SS
Page 52: ...21HF2 SS 9 2 2 BLOCK DIAGRAM MAIN UNIT A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Page 53: ...21HF2 SS 9 3 11 12 13 14 15 16 17 18 19 10 ...
Page 56: ...21HF2 SS 11 2 2 SCHEMATIC DIAGRAM MAIN UNIT A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Page 57: ...21HF2 SS 11 3 11 12 13 14 15 16 17 18 19 10 ...
Page 59: ...21HF2 SS 12 2 11 12 13 14 15 16 17 18 19 10 ...
Page 60: ...21HF2 SS 12 3 2 MAIN UNIT Wiring Side A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...