background image

PEX CLAMP TOOL – THREE HANDLE 

#865895

The PEX Clamp Tool will assemble 3/8", 1/2", 5/8", 3/4" and 1" stainless steel PEX clamps.  

When used properly, closed Oetiker clamps meet ASTM F2098 Specification

INSTRUCTION GUIDE

CONNECTION ASSEMBLY

Cut the tube so that a clean, straight end is provided. 

Slide the clamp over the tube end. Insert the fitting into 

the tubing until the shoulder of the fitting contacts the 

tubing end. Position the clamp 1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing.

Place the opened jaws of the PEX Clamp Tool over the raised ear of the clamp. Check to be sure that the 

clamp is still properly positioned. Compress the tool handles until the first “click” is felt. The clamp is now 

locked to the tubing. Compress the tool handles to complete the assembly. Note: The PEX Clamp Tool will  

not release until the assembly is completed.

CA865895INSTv

3

DISTRIBUTED 

        

BY RELIANCE WORLDWIDE 

CORPORATION

 

2727 Paces Ferry Road SE,  

Building II, Suite 1800,  

Atlanta, GA 30339 

T +1 877 700 4242

United States: Oetiker, Inc. 

6317 Euclid Street,  

Marlette, Michigan 48453 

T +1 800 959 0398

[email protected]
www.oetiker.com

TOOL CARE

When used and maintained properly the PEX 

Clamp Tool will provide years of trouble free service. 

Failure to provide basic tool care and maintenance 

will cause excess wear and possible premature 

failure. The following should be adhered to in order 

to maintain proper tool operation and Warranty 

coverage.

• 

Do not use the PEX Clamp Tool for any 

purpose other than to assemble clamps. 

• 

Lubricate the tool head, spring and ratchet 

mechanism once every thirty days with light 

lubricating oil, if tool operation becomes 

sluggish and after cleaning.

• 

Clean tool periodically to remove rust and dirt. 

CALIBRATION CHECK

• 

Close handle to stop point

• 

Insert gage into jaw gap

• 

Gage must stop at no-go

• 

If gage goes beyond this point re-calibrate tool

CALIBRATION PROCEDURE

• 

Loosen adjustment nut

• 

Place “Go” portion of gage into jaw gap

• 

Rotate eccentric stud counter clockwise until 

jaws contact gage

• 

Tighten nut

• 

Check tool with gage the first and last crimp 

of each job site.

WARRANTY INFORMATION

When properly maintained and used as intended, 

the PEX Clamp Tool is warranted against materials 

and manufacturing defects for a period of 1 year 

from date of purchase. This Warranty does not cover 

defects or damage arising from improper installation, 

lack of or improper maintenance, improper storage 

or handling, ordinary wear and tear, misuse, abuse, 

accident or use with unauthorized products or parts. 

Liability is limited to repair or replacement of tool or 

component parts which are determined defective as 

covered by this Warranty.
US Patent # 8,312,755

IN THE EVENT OF  

A JAM, COMPRESS 

HANDLES TO 

RELIEVE PRESSURE 

ON RATCHET, PULL 

RELEASE LEVER 

IN DIRECTION OF 

ARROW

GAGE

Reviews: