SharkBite 865894 Instruction Manual Download Page 1

1/2" & 3/4" LARGE PEX CRIMP TOOL 

#865894

CRIMPS CONFORM TO ASTM F 1807

INSTRUCTION GUIDE

CA865894INSTv

3

DISTRIBUTED BY  

RELIANCE WORLDWIDE CORPORATION

 

2727 

Paces Ferry Road SE, Building II, Suite 1800, 

Atlanta, GA 30339 | T +1 877 700 4242

United States: Oetiker, Inc. | 6317 Euclid Street 
Marlette, Michigan 48453 | T +1 800 959 0398
[email protected]

www.oetiker.com

ADJUSTMENT PROCEDURE

CONNECTION ASSEMBLY

CHECK ALL CRIMPS WITH GO/NO-GO GAGE

GAGING PROCEDURE

Cut the tube so that a clean, straight end is provided. Slide the crimp 
ring over the tube end. Insert the fitting into the tubing until the 
shoulder of the fitting contacts the tubing end. Position the crimp ring 

1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing.

Place the opened jaws of the PEX Crimp Tool around the crimp 
ring. Check to be sure that the crimp ring is still properly positioned. 
Compress the tool handles to complete the assembly.

1.

Determine proper size of tubing: 3/8”, 1/2", 3/4" or 1"

2. If GO cavity fits over crimped ring and NO-GO does not, tool is

crimping properly.

3. If GO cavity does not fit then handle distance must be increased.

4.

If GO fits—check NO-GO. If NO-GO fits over crimped ring, the
ring is over-crimped, decrease handle distance. Recheck.

NOTE: Over-crimped and under-crimped rings must be removed from 
tubing. Crimp with a new copper ring.

1.

Close tool handles until pre-load is reached (this is the point at 
which jaws touch). Tool should not be completely closed.

2. Measure the distance between dots on the handle ends as shown.

8 1/4"– 8 3/4" is the correct distance. If the distance is not 8 1/4" –
8 3/4" the tool must be adjusted.

3. To change the handle ends distance, remove the #6-32 eccentric 

lock screw with an Allen wrench and push up eccentric from back.
Rotate eccentric counter-clockwise to increase the handle distance
and clockwise to decrease handle distance. Move eccentric until
hand distance is between 8 1/4" – 8 3/4". Push down eccentric
and re-install the #6-32 lock screw in the appropriate hole which 
most closely yields the desired handle distance.

4.

Recheck the set distance after making three crimps. The distance
should be 8 1/4" – 8 3/4" between the “dots” on the handles.

5. Check the crimps with the go/no-go gauge provided. If satisfactory 

crimps do not result, the tool is likely worn and should be replaced.

WARRANTY

1.

Check tool calibration daily.
It is recommended that at

least the first and last crimps
of the day are tested.

2. Never exceed the specified

handle distance when
adjusting your crimp tool.
Premature wear will result.

3. Lubricate linkages on a

regular basis to maximize
tool life.

When properly maintained and 
used as intended, the PEX Crimp 
Ring Tool is warranted against 
materials and manufacturing 
defects for a period of 1 year from 
date of purchase. This Warranty 
does not cover defects or damage 
arising from improper installation, 
lack of or improper maintenance, 
improper storage or handling, 
ordinary wear and tear, misuse, 
abuse, accident or use of parts 
with unauthorized products or 
parts. Liability is limited to repair  
or replacement of tool or 
component parts which are 
determined defective as covered 
by this Warranty.

8 1/4"– 8 3/4"

HANDLE PRE-LOAD

Gage all crimps as shown.

“DOTS”

TOOL MAINTENANCE

Eccentric

Lock 

Screw

Reviews: