High-Flying
HF-LPT120 Low Power WiFi Module User Manual
Shanghai High-Flying Electronics Technology Co., Ltd(www.hi-flying.com)
- 50 -
Yes: Disable power save
mode:
No: Enable power save
Yes: Disable power save
4.2.2.56.
AT+NTPRF
Function: Set /Query time calibration interval
Format:
Query Operation
AT+NTPRF<CR>
+ok=<num><CR><LF><CR><LF>
Set Operation
AT+NTPRF=<num><CR>
+ok<CR><LF><CR><LF>
Parameters:
num
:
time calibration inverval
,
range:0~720, default:30 minutes, 10 minutes for
each step, set 0 means no time calibration automatically.
4.2.2.57.
AT+NTPEN
Function: Enable/Disable time calibration function. Setting is valid after reset.
Format:
Query Operation
AT+NTPEN<CR>
+ok=<status><CR><LF><CR><LF>
Set Operation
AT+NTPEN=<status><CR>
+ok<CR><LF><CR><LF>
Parameters:
status
:
status of time calibration
on
:
Enable time calibration
off
:
Disable time calibration
4.2.2.58.
AT+NTPTM
Function: Query network time,time zone is GMT+8 by default.
Format:
Query Operation
AT+NTPTM<CR>
+ok=<time><CR><LF><CR><LF>
Parameters:
time
:
networ time, for example: 2013-10-9 16:10:42 Wed
,
if it shows Not
Available means that the time calibration function is not enabled or the module
doesn’t connect to the internet.
4.2.2.59.
AT+NTPSER
Function: Set/Query NTP server IP address..