SGS SC100V Owner'S Manual Download Page 1

FOR YOUR SAFETY
PLEASE READ THESE INSTRUCTIONS CAREFULLY
AND RETAIN THEM FOR FUTURE USE.

OWNER’S MANUAL

SC100V
AIR COMPRESSOR

Summary of Contents for SC100V

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SC100V AIR COMPRESSOR...

Page 2: ...ery 14 6 CFM Discharge Pressure 115 PSI 0 8 MPa Restart Pressure 80 PSI 0 55 MPa Tank Capacity 100 L Dimensions 1090x430x830 mm Air Outlet Size 1 4 Noise Specification LWA 97dB Net Weight 57 kg LIST O...

Page 3: ...MAIN COMPONENTS 1 Main compressor 2 Pressure switch 3 Outlet Valve 4 Regulating Valve 5 Pressure gauge 6 One way Valve 7 Drain cock 8 Wheels 9 Air tank 10 Safety valve 11 Fan cover 1 2 3 4 5 6 7 8 9...

Page 4: ...power cut and subsequent reset Do not carry the compressor while it is connected to the power source or when the tank is filled with compressed air This compressor contains surfaces which may reach a...

Page 5: ...tion Eye protectors must provide protection from flying particles both from the front and from the side PROTECT YOUR HEARING Hearing protection should be worn when operating this compressor use ear pl...

Page 6: ...do not touch DO NOT DIRECT AN AIR STREAM AT THE BODY Do not direct the air stream at people or animals as injury may result Com pressed air can cause soft tissue damage and propel dirt and other part...

Page 7: ...connecting the air compressor to the mains supply make sure the red button on top of the air compressor is in the OFF down position STORE THE AIR COMPRESSOR PROPERLY When not in use the air compressor...

Page 8: ...ould be disposed of in a safe an environmentally friendly manner Contact your local Council for disposal assistance DO NOT WELD TO THE PRESSURE VESSEL Do not weld or modify the pressure vessel in any...

Page 9: ...PAGE 9 ASSEMBLY Use a spanner to attach the wheels to the compressor Use the washers and spring washer in the positions shown Insert the support foot into the position shown...

Page 10: ...starting 2 Before running the compres sor remove the plug and con nect the breather pipe to the oil hole 2 3 Screw both the air filters in either side before starting the compressor 3 4 Set the compre...

Page 11: ...glass sight win dow You can purchase compres sor oil from our website at www sgs engineering com 6 Open the outlet valve set the power switch knob to posi tion on and let the compres sor run for 10 mi...

Page 12: ...s been adjusted during the manufacturing process don t alter it carelessly As soon as the motor is switched off the compressed air in the discharge pipe should be released through the release valve un...

Page 13: ...RIGHT shows the current pres sure in the reservoir tank 2 The pressure gauge on the LEFT shows the user set outlet pressure This can be adjusted using the regulator 2 The output pressure of compressed...

Page 14: ...pped set the pressure switch in the off position 4 Always vent the compressor after each use by turning the regulator knob fully anticlock wise 5 Once the compressor is vent ed remove any condensation...

Page 15: ...and replenish if neces sary you can replenish by unbolting the oil level sightglass and draining off any old oil 2 3 Have the safety valve and pressure gauge checked by a certified repair centre every...

Page 16: ...m the filters 3 Remove the filters from the filter covers 4 Clean the sponge and both the filters cover using a soft brush If necessary the filters can be care fully cleaned in warm soapy water Rinse...

Page 17: ...rvoir pressure decreases for no apparent reason it is possible that the non return valve is leaking To check 1 Make sure that the reservoir is not under pressure and the compressor is switched OFF 2 E...

Page 18: ...If it cuts out this is a safety feature to protect you and your compressor Leave this compressor for a good while until you reset it If the compressor turns off again on re set you should not keep run...

Page 19: ...oreign body in the main compressor 3 Piston knocking the valve seat 4 Moving parts seriously worn 1 Check and retighten 2 Check and clean away 3 Replace with thicker paper gasket 4 Repair or replace P...

Page 20: ...PAGE 20 REPLACEMENT PARTS DIAGRAM WWW SGS ENGINEERING COM...

Page 21: ...04 1 29 Capacitor W 1 30 Nut M8 2 31 Capacitor B 1 32 Prop 1 33 Bolt M8x25 4 ITEM PART QTY 34 90 Elbow 1 35 Connector 1 36 90 Elbow T pc 1 37 Air Filter 2 38 Stator 1 39 Rotor 1 40 Bearing 1 41 Wave W...

Page 22: ...Ltd West Side Park Raynesway Derby DE21 7AZ Air Compressor SC100V EN 1012 1 2010 AfPS GS 2014 01 PAK EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 Machinery Directive 2006 42 EC Low Voltage Directive 2...

Reviews: