The EFOY Pro fuel cell is capable to receive commands from an external controller. To use this functionality you can 
send serial commands or use switching contacts of “Data Interface”. To use external control functionality, EFOY Pro 
offers three possibilities: 

 

1) Button commands via serial communication 

Via serial communication (RS-232) the same commands triggered by the buttons of EFOY Pro’s remote control can be 
sent to the fuel cell. Three commands „Button On“, „Button Off“ and „Button Auto“ cover this functionality. The fuel cell 
reacts the same way as if these buttons are used on EFOY Pro’s remote control. Details for setting up serial 
communication are described in the manual for Interface Adapter. 

 

2) „Remote On“ Signal 

If EFOY Pro receives  „Remote On“ signal by switching contacts of serial communication it starts the charging cycle until 
switch off voltage is reached. In the display of the remote control you can see „R“ or “RC” as long as “Remote On” Signal 
is active. Is „Remote On“ signal still active after a complete charging cycle, another charging cycle will start. Therefore 
we recommend to reset „Remote On“ signal after charging cycle has started. 

INFO: During operation mode „manual off“ the EFOY Pro will directly shut down, when the „Remote On“ signal is not 
active anymore. If the EFOY Pro should perform a charging cycle, it has to be in „Automatic“ mode.   

 

Switching contacts on data interface: 

 

 

Pin 

Function 

1  DuoCartSwitch 
2  RxD (Data) 
3  TxD (Data) 
4  GND, Ground 
5  B 
6  Fuel Cartridge Sensor 

7  Remote On 
8  Hybrid 