SFA SANICUBIC 1 SC Series Operating Instructions Manual Download Page 1

Sewage Lifting Units

 

Operating instructions

Abwasserhebeanlagen 

Betriebsanleitung

Station de relevage des eaux usées

 

Mode d'emploi

Stazione di pompaggio acque reflue 

Istruzioni per l'uso

Afvalwater Opvoerinstallaties

 

Gebruikshandleiding

Equipos elevadores de aguas residuales 

Manual de instrucciones

Unidades elevatórias de águas residuais 

 

Manual de instruções

SANICUBIC

®

 SC

SANICUBIC

®

 1 SC          SANICUBIC

®

 2 SC

IT

NL

ES

PT

UK

DE

FR

9011

10.19

Summary of Contents for SANICUBIC 1 SC Series

Page 1: ...Mode d emploi Stazione di pompaggio acque reflue Istruzioni per l uso Afvalwater Opvoerinstallaties Gebruikshandleiding Equipos elevadores de aguas residuales Manual de instrucciones Unidades elevatórias de águas residuais Manual de instruções SANICUBIC SC SANICUBIC 1 SC SANICUBIC 2 SC IT NL ES PT UK DE FR 9011 10 19 ...

Page 2: ...English 3 Deutsch 17 Français 31 Italiano 45 Nederlands 59 Español 73 Português 87 ...

Page 3: ...ce inspection and installation work pg 5 1 7 Unauthorised modification and spare parts production pg 6 1 8 Impermissible operating modes pg 6 2 GENERAL ASPECTS pg 6 2 1 Affiliation pg 6 2 2 Inquiries and purchase orders pg 6 2 3 Technical data pg 6 2 4 Field of application pg 7 2 5 Accessories pg 8 3 TRANSPORT AND INTERMEDIATE WAREHOUSING pg 8 3 1 Transport pg 8 3 2 Intermediate warehousing conser...

Page 4: ...mer service team or a similarly qualified individual These operating instructions contain basic instructions which have to be observed during set up operation and maintenance For this reason these operating instructions must by all means be read before installation and commissioning by the installation technician as well as by the competent specialist staff user and must be permanently available a...

Page 5: ...ating instructions the existing national regulations on accident prevention as well as potential in company work operating and safety instructions of the user must be observed 1 5 Safety instructions for user operator If hot or cold machine parts could lead to hazards these parts have to be protected against touch by the user Touch protection for moving parts e g coupling must not be removed from ...

Page 6: ...ufacturer assumes no lia bility for any damage resulting from this As any other electrical appliance this product can also fail due to missing main power or a technical defect If a damage can occur as a result an emergency power generator a man ual membrane pump a second system double system and or a mains independent alarm system should be planned according to the application We as manufacturers ...

Page 7: ...quirement m SANICUBIC 2 SC3 0 T 1000 500 DN 150 80 370 1450x950 2 5x1 5 SANICUBIC 2 SC4 0 T 1000 500 DN 150 80 385 1450x950 2 5x1 5 SANICUBIC 2 SC5 5 T 1000 500 DN 150 100 400 1450x950 2 5x1 5 SANICUBIC 1 SC7 5 T 1000 500 DN 150 100 425 1450x950 2 5x1 5 Maximum media temperature 55 C Materials Shaft sealing Motor side Shaft seal Pump side up to 4 kW mechanical seal from 5 5 kW chilled casting seal...

Page 8: ...r natural gradient flows into the collecting tank of the sewage lifting unit SANICUBIC SC The collecting tank is designed for pressureless operation that is the occurring waste water is buffered without pressure and then conveyed into the sewage channel In the dip tube that is screwed on the upper side of the tank the water rises and keeps compressing the air being in the dip tube so long until th...

Page 9: ...unit has to be secured by means of suitable attachment equipment on site against twisting and buoyant floating 5 2 2 Inlet The inlet line is connected to the flange DN 150 It must always be installed on a downhill incline Uphill sections in the inlet are not permitted 5 2 3 Discharge line Installation of a non return valve in the discharge line of the lifting unit must always be installed DIN 19 7...

Page 10: ...he socket and the pump s direction of rotation checked This is done by briefly setting the manual 0 automatic switch to Manual When the motor comes to a standstill the direction of rotation can be compared with the correct direction of rotation rotation arrow on the top surface at the sight glass If the pump rotates the wrong way round two of the three phases will have to be interchanged All power...

Page 11: ...e spare parts list must not be loosened because otherwise the mechanical seal is destroyed oil escapes and the warranty will become void If only the motor unit shall be dismounted all 4 screws Item 13 of the spare parts list have to be loosened If the complete pump shall be dismounted from the tank all 4 nuts item 23 of the spare parts list must be loosened Malfunction Cause Troubleshooting 1 Moto...

Page 12: ...omer service Customer service 4 Motor does not switch off Controlling error Pitot tube clogged Customer service department Replacement Customer service department 9 WARRANTY As manufacturer we assume a warranty for this device for 24 months as of purchase date The sales receipt is considered as proof of warranty Within this warranty period we will at our dis cretion either by means of repair or re...

Page 13: ...13 Appendix A Assembly example ...

Page 14: ...14 Appendix B Dimensions SANICUBIC 1 SC SANICUBIC 2 SC ...

Page 15: ...ctional drawing Spare parts list Switchgears Quantity Designation Article No 1 Switchgear ZPS1 3 0 4 0 5 5 kW 256300 1 Switchgear ZPS1 SD 7 5 kW 215402 1 Switchgear ZPS2 3 0 4 0 5 5 kW 255400 1 Switchgear ZPS2 SD 7 5 kW 215403 1 1 Small compressor set 71035 ...

Page 16: ... screw M 10 x 30 SANICUBIC SC 3 0 and 4 0 ZE1237 8 16 Hexagon screw M 12 x 30 SANICUBIC SC 5 5 and 7 5 ZE1516 15 1 2 Motor unit 3 0 kW with impeller 111103 1 2 Motor unit 4 0 kW with impeller 111104 1 2 Motor unit 5 5 kW with impeller 111107 1 2 Motor unit 7 5 kW with impeller 111108 16 4 8 Hexagon screw M 12 x 25 ZE1130 4 8 Spring washer B 12 ZE1302 17 1 2 Impeller D 200 mm 3 0 kW 120134c 1 2 Imp...

Page 17: ......

Page 18: ...ROMANIA SFA SANIFLO S R L 145B Foisorului Street District 3 31177 BUCURESTI Tel 40 787 634 557 info saniflo ro TÜRKIYE SFA SANIHYDRO LTD ŞTİ Mecidiye Cad No 36 B Sevencan Apt 34394 MECIDIYEKOY ISTANBUL Tel 90 212 275 30 88 CHINA SFA 中国 上海市静安区石门二路333弄3号振安广 场恒安大厦27C室 200041 Tel 86 0 21 6218 8969 Fax 86 0 21 6218 8970 BRAZIL SFA Brasil Equipamentos Sanitários Rua Maria Figueiredo 595 CEP 04002 003 Sã...