12
4 Performing a correlation measurement
CAUTION!
If a peak is displayed right in the centre of the screen,
this may indicate that the
RT 06
radio transmitter is
placed too close to the
SeCorr 08
(receiver). In this
case, increase the distance (5 – 10 m).
4.3.1 Filtering
Please read section 7.4 and 7.4.2 on the basic principles of fil
-
tering.
The filtering option here from the function in the main screen of
-
fers faster access to manual functioning than via Menu / Filter /
Manual. The range of functions here is, however, limited.
Select “Filter“ in the main screen.
z
The left filter limit flashes and can be set.
z
Enter key: calculates the result function; the other filter limit can
z
be set (can be repeated as often as you wish).
ON key: returns to the main screen, the result is displayed.
z
4.3.2
Cursor
After selecting the Cursor func
-
tion with the
Arrow keys
, you
can move the cursor to any
position using the
Arrow keys
or
Rotary regulator
.
Depending on the highlighted
position, the measurement result
is immediately recalculated. The
time indicated next to the cursor
represents the set time-delay
difference.
Below the correlation function,
the distance between the cur-
rent cursor position and the two
microphones is displayed.