10
2 Features
2.3.2
Active explosion protection
The functional safety test applies to:
Applications:
Warning %LEL
Warning ExTox
Gas types:
Measuring range:
– Methane CH
4
0 – 100% LEL
– Propane C
3
H
8
0 – 100% LEL
Gases:
Measuring range:
As per:
– Oxygen O
2
0 – 25 % O
2
– Carbon dioxide CO
2
0 – 5 % CO
2
– Carbon monoxide CO
0 – 500 ppm CO
– Hydrogen sulphide H
2
S
0 – 100 ppm
Tested accessories:
– Test set SPE VOL
– Flexible hand probe, 1 m
– Floating probe 2 m / 6 m
Type examination
Testing institute:
DEKRA EXAM GmbH
Certificates:
PFG 08 G 002 X
BVS 09 ATEX G 001 X
The following points were not part of the type examination:
●
Saving measurement data (see section 3.2.12
)
●
Saving protocols from the integrated device inspection (see
●
Disposable alkaline batteries for the power supply (see sec-
)