28
Manual – MOVIDRIVE® MDX61B Synchronous Operation Board DRS11B
6
Signaling functions
Parameter
6.2
Signaling functions
The following operating statuses are output:
•
Optical display via LED "SYNC" (green) "Counter LED display" (P514):
LED "SYNC" can be used to visualize the current maximum difference between the
master and slave drives during startup:
– ON = Angle difference > value of P514
– OFF = Angle difference < value of P514
•
Optical display of operating mode via LED "OFF" (red) "SLAVE FREE RUNNING":
– ON = Slave drive is in free-running mode
– OFF = Slave drive is in synchronous operation mode
•
Status signal "DRS SLAVE IN POS":
– on one of the programmed binary outputs (P60_/P61_)
•
Message "/DRS PREWARN.":
– on one of the programmed binary outputs (P60_/P61_)
•
Fault message "/DRS LAG ERROR":
– on one of the programmed binary outputs (P60_/P61_)
– with selectable fault response of the drive (P834)
P6..
P60.
P600