6
Electrical installation
Safety notes
Operating Instructions – SLC Synchronous Linear Motors
25
6
Electrical installation
DANGER
Risk of injury due to electric shock.
Severe or fatal injuries.
•
Strictly observe the safety notes in the individual chapters.
•
When motors are powered from inverters, you must observe the wiring instruc-
tions issued by the inverter manufacturer. Observe the operating instructions of
the inverter.
INFORMATION
A bag containing the following information is attached to the motor:
Safety notes
Observe the following notes.
6.1
Safety notes
EMC measures
The designated use of SEW‑EURODRIVE synchronous linear motors is as compon-
ents for installation in machinery and systems. The manufacturer of the machine or
system is responsible for complying with the EMC Directive 2014/30/EU.
Encoder connec-
tion
Observe the following instructions when connecting an encoder:
•
Use a shielded cable with twisted pair conductors only.
•
Connect the shield to the PE potential on both ends over a large surface area.
•
Install signal cables separately from power cables or brake cables (min. distance
200 mm [7.87 in]).
22488669 /EN – 06/2016