5
Single-point synchronization
Restrictions of the parameters
Product Manual – MOVITRANS
®
TES31A Decentralized Supply Unit Synchronization
29
Index
Parameter
Restrictions
Dec
Hex
Sub
8594
2192
0
Factory settings
In contrast to the conventional unit
behavior, when performing factory
settings with the setting "Basic ini-
tialization" or "Standard" a station
configured as "SP slave" is also
given its configuration. If the station
was previously configured as "SP
master", it is configured as an "SP
slave" after the factory setting. The
desired setting must therefore be
adjusted accordingly.
10233
27F9
1
Frequency mode
Setting blocked.
10422
28B6
1
Sync phase angle
Setting range restricted to 0° - 10°
(increasing) and 360° - 350° (de-
creasing).
Function
Restriction
Control word
For all slave stations, the control word is
subject to the restriction that only the Bit6
can be used as a fault reset bit. All other
commands are ignored in the configura-
tion as a slave. Similarly, the control sig-
nal source cannot be set on SBus2 when
the interface is used as the synchroniza-
tion signal.
Technology function
Modify this only after consultation with
SEW‑EURODRIVE.
29190657/EN – 04/2020