6
Line chokes
Technical data
Manual – Accessories
33
6.2
Technical data
6.2.1
IP20, 1 x 230 V, 3 x 230 V, 6 – 36 A
Type
Unit
ND LT 016 180
21-20
ND LT 025 110
21-20
ND LT 006 480
53-20
ND LT 010 290
53-20
ND LT 036 081
53-20
Part number
28233417
18201652
18201660
18201679
18201687
Nominal voltage U
N
(in ac-
cordance with EN 50160)
V
1 x AC 230, 50/60 Hz
3 x AC 230 – 500, 50/60 Hz
Rated current I
N
A
16
25
6
10
36
Inductance L
N
mH
1.8
1.1
4.8
2.9
0.81
Ambient temperature
°C
-25 to +45
IP degree of protection
IP20 (EN 60529)
Mass
kg
1.1
1.8
1.3
2.5
7.2
Assignment for LTE-B: AC
230 V
AC 400 V
0004 − 0015
0022
0004/0008
0015
0022/0040
–
–
0008/0015
0022
0040 – 0110
Assignment for LTP-B: AC
230 V
AC 400 V
0008/0015
0022
0008
0015
0022 – 0055
–
–
0008/0015
0022/0040
0055 – 0150
UL/cUL approval
No
No
No
No
No
6.2.2
IP00/IP20, 3 x 230 – 500 V, 50 – 300 A
Type
Unit
ND LT 050 058 53-20
ND LT 090 032 53-20
ND LT 200 007 53-00
ND LT 300 005 53-00
Part number
18410936
18410944
28233433
28233441
Nominal voltage U
N
(in ac-
cordance with EN 50160)
V
3 x AC 230 – 500, 50/60 Hz
Rated current I
N
A
50
90
200
300
Inductance L
N
mH
0.58
0.32
0.0735
0.049
Ambient temperature
°C
-25 to +40
IP degree of protection
IP20 (EN 60529)
IP00 (EN 60529)
Mass
kg
8.7
16
35
48
Assignment for LTP-B: AC
230 V
AC 400 V
0075 – 0110
0150 – 0185
0220 – 0450
0550/0750
0185 – 0220
0300 – 0370
0450 – 0900
1100 – 1600
UL/cUL approval
No
No
No
No
6.2.3
IP66, 1 x 230 V, 3 x 230 – 600 V, 6 – 25 A
Type
Unit
ND LT 016 183
21-66
ND LT 025 117
21-66
ND LT 006 480
63-66
ND LT 010 386
63-66
ND LT 018 204
63-66
Part number
18217680
18217699
28233409
18217710
28233425
Nominal voltage U
N
(in ac-
cordance with EN 50160)
V
1 x AC 230, 50/60 Hz
3 x AC 230 – 600, 50/60 Hz
Rated current I
N
A
16
25
6
10
18
Inductance L
N
mH
1.83
1.17
4.8
3.86
2.04
Ambient temperature
°C
-25 to +40
IP degree of protection
IP66 (EN 60529)
Mass
kg
1
1.3
1.6
3.5
7
Assignment for LTE-B: AC
230 V
AC 400 V
0004 − 0015
0022
0004/0008
0015
0022/0040
–
–
0008/0015
0022
0040 – 0110
Assignment for LTP-B: AC
230 V
AC 400 V
AC 575 V
0008/0015
0022
0008
0015
0022/0030
–
–
0008/0015
0022
0040/0055
–
–
0008 – 0022
0040
0055/0075
UL/cUL approval
No
No
No
No
No
23540052/EN – 06/2018