8
134
System Manual – MOVITRAC® 07
Touch guard
Installation
For size 2
SEW-EURODRIVE supplies a power shield clamp with two retaining screws as stan-
dard with MOVITRAC
®
07 size 2. Install this power shield clamp together with the two
retaining screws on X6.
1. Shield clamp
2. PE connection (y)
Power shield clamps provide you with a very convenient way of installing the shield for
the motor and brake leads. Install the shield and PE conductor as shown in the figures.
8.4
Touch guard
SEW-EURODRIVE supplies two touch guards with eight retaining screws as standard
with MOVITRAC
®
07 size 4. Install the touch guard on the two hood covers for the power
section terminals.
When the touch guard is installed, MOVITRAC
®
07 size 4 has enclosure IP10. The units
have IP00 without touch guard.
01469BXX
Figure 75: Power shield clamp for MOVITRAC
®
07 size 2
01470BXX
Figure 76: Touch guard for MOVITRAC
®
07 size 4