Manual – MOVIPRO® SDC with DeviceNet Interface
8
Overview of process data
Process Data Description
8
Process Data Description
8.1
Overview of process data
The following illustration provides an overview of the assignment of the process output/
input data (PO/PI) of MOVIPRO
®
SDC:
8.2
MOVIPRO
®
control word
The following figure shows the assignment of the MOVIPRO
®
control word:
The following table shows the functions of the MOVIPRO
®
control word:
Power section based on MOVIDRIVE
®
platform
→
MOVIPRO
®
control word
4 DIO
PO1
PO2
PO3
PO4
PO5
PO6
→
Master
MOVIPRO
®
Power section based on MOVIDRIVE
®
platform
←
MOVIPRO
®
status word
12 DI
PI1
PI2
PI3
PI4
PI5
PI6
←
Master
→
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
→
MOVIPRO
®
0 – 4: Reserved = 0
5: Reset application
6: Reset system
7: Reserved = 0
8 – 15: Reserved = 0
Bit
Meaning
Explanation
0 – 4
Reserved
0 = reserved
5
Reset application
If there is an error in the "PFH.." communication
and control unit, an error reset is requested by
changing this bit from 0 to 1 to 0.
6
Reset system
If there is an error in the "PFH.." communication
and control unit, an error reset is requested by
changing this bit from 0 to 1 to 0.
7 – 15
Reserved
0 = reserved
0
0
I