Manual – MOVIPRO® SDC with DeviceNet Interface
45
6
Common Industrial Protocol (CIP)
DeviceNet Operating Characteristics
Parameter object
• The fieldbus parameters of the MOVIPRO
®
can be addressed directly via the
instance with the parameter object.
• In exceptional cases, you can also use the parameter object to access SEW
parameters.
• Class code: 0F
hex
Class
Instance 1 – 133
Instances 1 – 133 give access to the fieldbus parameters.
Fieldbus parame-
ters of MOVIPRO
®
The following table shows the fieldbus parameters of MOVIPRO
®
:
INFORMATION
The data format for these instances deviates from the SEW fieldbus profile to meet the
DeviceNet specification.
Attribute
Access Name
Data type
Default value
[hex]
Description
2
Get
Max Instance UINT
0085
Maximum instance = 133
8
Get
Parameter
Class
Descriptor
UINT
0009
Bit 0: Supports parameter instances
Bit 3: Parameters are stored in a
non-volatile manner
9
Get
Configura-
tion Assem-
bly Interface
UINT
0000
Configuration assembly is not sup-
ported.
Attribute Access
Name
Data type
Default value
[hex]
Description
1
Set/Get
Parameter
UINT
206C
Parameter to be read or written,
See table "Fieldbus parameters of
MOVIPRO
®
"
2
Get
Link Path
Size
USINT
00
Not used
3
Get
Link Path
Packed
EPATH
00
Not used
4
Get
Descriptor
WORD
0000
Read/write parameter
5
Get
Data type
EPATH
00C8
UDINT
6
Get
Data Size
USINT
04
Data length in bytes
Instance
Access
Group
Name
Meaning
1
Get/Set
Device
parameter
PD configuration
Process data configuration
2
Get
Timeout time
Timeout interval
3
Get
Fieldbus type
DeviceNet
4
Get
Baud rate
Baud rate via DIP switches
5
Get
Station address
MAC-ID via DIP switches
6 – 69
Get
PO moni-
tor
PO1 setpoint
PO64 setpoint
Monitor of the process output data words
70 – 133
Get
PI monitor
PI1 actual value
PI64 actual value
Monitor of the process input data words