Manual – MOVIPRO® SDC with DeviceNet Interface
10
Explanation of the parameters
Parameterization of MOVIPRO
®
P864 PWM fre-
quency CFC
Setting range: 4 / 8 / 16 kHz
P864 can be used in "CFC" and "Servo" operating mode to set the switching frequency
at the inverter output for parameter set 1. The cycle frequency is set to a fixed value and
is not automatically reduced with high unit utilization.
P87x Process data description
P870/P871/P872
Setpoint descrip-
tion PO1/PO2/PO3
P870/P871/P872 define the content of the process output data words PO1/PO2/PO3.
This is necessary so that the power section can allocate the appropriate setpoints.
The following PO assignments are available:
See the "Fieldbus unit profile with parameter list" manual for detailed explanations.
P873/P874/P875
Actual value
description PI1/
PI2/PI3
P873/P874/P875 define the content of the process input data words PI1/PI2/PI3. This is
necessary so MOVIPRO
®
can allocate the appropriate actual values.
The following PI assignments are available:
Setpoint description
Factory setting
P870 Setpoint description PO1
Control word 1
P871 Setpoint description PO2
Setpoint speed
P872 Setpoint description PO3
Ramp
Assignment
Description
No function
The content of the process output data word is ignored.
Setpoint speed
Setpoint speed in rpm
Set current
Current setpoint selection (for torque control)
Set position low
Setpoint position low word
Set position high
Setpoint position high word
Max. speed
Maximum system speed (P302 / P312)
Max. current
Current limitation in % of I
N
of the inverter (P303/P313)
Slip speed
Slip compensation (P324/P334)
Ramp
Ramp time for setpoint selection
Control word 1
Control signals for start/stop, etc.
Control word 2
Control signals for start/stop, etc.
Setpoint speed
[%]
Selection of a speed setpoint in % of n
max
IPOS PO data
Specification of a 16-bit coded value for IPOS
plus®
(application module only)
Actual value description
Factory setting
P873 Actual value description PI1
Status word 1
P874 Actual value description PI2
Actual speed
P875 Actual value description PI3
Output current
Assignment
Description
No function
The content of the process input data word is 0000
hex
Actual speed
Current speed actual value of the drive in min
-1
Output current
Instantaneous output current of the system in % of I
N
Active current
Current active current of the system in % of I
N
:
•
Positive sign = Positive torque
•
Negative sign = Negative torque
Actual pos. low
1)
Current actual position low word.
The actual position is read from
P941
Actual position source
(page 129).
Actual pos. high
Current actual position high word
0
0
I