
8
Service
Failures of the mechanical drive
Operating Instructions – MOVIMOT
®
advanced
133
8.1.2
Brake malfunctions
Fault
Possible cause
Measure
Brake does not re-
lease
Electronics cover defect-
ive
•
Contact SEW‑EURODRIVE
Service
•
Replace electronics cover
Max. permitted working
air gap exceeded be-
cause brake lining worn
down
•
Contact SEW‑EURODRIVE
•
Have brake lining replaced by
SEW‑EURODRIVE Service or
a qualified technician trained
by SEW‑EURODRIVE
Brake defective
•
Contact SEW‑EURODRIVE
•
Have brake replaced by
SEW‑EURODRIVE Service or
a qualified technician trained
by SEW‑EURODRIVE
Motor does not
brake
Brake lining worn
•
Contact SEW‑EURODRIVE
•
Have brake lining replaced by
SEW‑EURODRIVE Service or
a qualified technician trained
by SEW‑EURODRIVE
Incorrect braking torque
•
Contact SEW‑EURODRIVE
•
Have braking torque changed
by SEW‑EURODRIVE
Service or a qualified techni-
cian trained by
SEW‑EURODRIVE
Oil leakage (only with
gearmotors)
•
Contact SEW‑EURODRIVE
•
Have leakage remedied by
SEW‑EURODRIVE Service or
a qualified technician trained
by SEW‑EURODRIVE
25891936/EN – 05/2020