7
Operation
Function "Releasing the brake / deactivating DynaStop® with FCB 01"
Operating Instructions – MOVIMOT
®
advanced
129
7.4
Function "Releasing the brake / deactivating DynaStop
®
with FCB 01"
Function
"Releasing
the brake /
deactivatin
g
DynaStop®
with FCB
01"
7.4.1
Activating the function
WARNING
Risk from falling loads.
This can result in severe or fatal injuries.
•
Do
not
use the function "Releasing the brake / deactivating DynaStop
®
with
FCB 01" for hoist applications and applications with potentially falling loads.
•
Inhibit the function via the following steps:
– Deactivate the function of the DIP switch S1/2 using the parameter
Deactiva-
tion
=
"1"
(path:
Functions
>
Inputs/outputs
>
Basic device
>
DIP switch func-
tions
>
Releasing the brake / deactivating DynaStop
®
with FCB 01 – enable
)
– Inhibit the functions using the parameter
Releasing the brake / deactivating
DynaStop
®
with FCB 01 – enable
=
"0"
(path:
Functions
>
Drive functions
>
FCB 01 Output stage inhibit
).
In case the output stage is inhibited, you can release the brake by a control signal (di-
gital input or process data bit) using the function "Releasing the brake / deactivating
DynaStop
®
with FCB 01". For example, this allows to move loads freely using a hori-
zontal conveyor.
Now make the following settings:
1.
Enabling the function
:
•
Via DIP switch S1/2
Set the DIP switch S1/2 "Releasing the brake / deactivating DynaStop
®
with
FCB 01 – enable" = ON.
•
Via parameter settings
Deactivate the DIP switch S1/2 by setting the parameter
Deactivation
=
"1"
.
(Path:
Functions
>
Inputs/outputs
>
Basic device
>
DIP switch functions
>
Re-
leasing the brake / deactivating DynaStop
®
with FCB 01 – enable)
Enable the function "Releasing the brake / deactivating DynaStop
®
with FCB 01
– enable" by setting the parameter
Releasing the brake / deactivating
DynaStop
®
with FCB 01 – enable
to
"1"
[1].
(Path:
Functions
>
Drive functions
>
FCB 01 Output stage inhibit
)
[1]
18014420484359179
2.
Configuring the control signal
:
25891936/EN – 05/2020