6
Startup
DIP switches
Operating Instructions – MOVIMOT
®
advanced
105
6.5
DIP switches
6.5.1
Overview
NOTICE
Damage to the DIP switches caused by unsuitable tools.
Possible damage to property.
•
To set the DIP switches, use only suitable tools, such as a slotted screwdriver
with a blade width of no more than 3 mm.
•
The force used for setting the DIP switches must not exceed 5 N.
The following figure shows the DIP switches of the drive unit:
S1 1 2 3 4 1 2 3 4 S2
4 S2
t1
On
Off
f1
f2
4
3
2
1
ON
4
3
2
1
ON
3
56
4
7
ON
1
2 3
4
S1
ON
1
2 3
4
S2
ON
1
S3
2 3 4 5 6 7 8 9 10
9007228267677579
DIP switch S1
The following table shows the functions of DIP switch S1:
DIP switch
S1
1
2
3
4
Meaning
Direction of
rotation
reversal
Releasing the
brake /
deactivating
DynaStop
®
with
FCB 01 – en-
able
Speed moni-
toring
deactivation
Reserved
ON
On
On
Speed
monitoring
Off
On
OFF
Off
1)
Off
1)
Speed
monitoring
On
1)
Off
1)
1) The factory settings are shown in boldface.
25891936/EN – 05/2020