12
Functional safety
Connections variants
Operating Instructions – MOVIGEAR
®
performance
389
12.4.4
Connection variant 2: M12 plug connector X5504/X5505 at the connection box
For further information on the connection of X5504/X5505, refer to the chapter "Elec-
trical installation" > "Assignment of optional plug connectors".
Wiring diagrams
Delivery state
In the delivery state, plug connector X5504 is not connected, this means the STO in-
put is active. According to the safety concept, X5504 must be connected or temporar-
ily jumpered using the optionally available STO jumper plug for staring up the unit.
2-pole sourcing
X5504
F_STO_P1
F_STO_M
F_STO_P2
[1]
2
5
4
[2]
GND
F-DO_P2
F-DO_P1
23876274315
[1] Drive unit
[2] External safety device
2-pole sourcing/sinking
X5504
F_STO_P1
F_STO_M
F_STO_P2
[1]
2
5
4
[2]
F-DO_P
F-DO_M
23876260491
[1] Drive unit
[2] External safety device