12
Functional safety
Connections variants
Operating Instructions – MOVIGEAR
®
performance
383
12.4.3
Connection variant 1: Terminal X9 in the connection box
For detailed information on terminal X9, refer to the chapter "Electrical Installa-
tion" > "Terminal assignment".
Wiring diagrams
Delivery state
In delivery state, the terminals at the connection for safe disconnection X9 are
jumpered. The jumpers are marked with the text "Caution, remove jumper for safety
operation". To use the drive unit in safety-related applications, remove the jumpers
from the STO terminal X9.
2
X9
1
3
4
11
F_STO_P1
F_STO_P1
0V24_OUT
24V_OUT
F_STO_M
[1]
21
F_STO_P2
22
F_STO_P2
12
F_STO_M
9007222815498379
[1] Drive unit
2-pole sourcing
[2]
11
X9
1
21
F_STO_P1
F_STO_M
F_STO_P2
3
4
0V24_OUT
24 V_OUT
F-DO_P1
F-DO_P2
GND
[1]
2
F_STO_P1
12
F_STO_M
F_STO_P2
22
9007222818851979
[1] Drive unit
[2] External safety device
25945475/EN – 04/2019