11
Technical data and dimension sheets
Technical data
Operating Instructions – MOVIGEAR
®
performance
310
11.3.6
DC 24 V auxiliary output
Internal voltage supply, only for non-safety-related enable signal via STO input
DC 24 V output
X9
24V_OUT
U
OUT
= DC 24 V -10%/+20% according to EN 61131-2
External-voltage-proof and short-circuit proof
Permitted output current: I
OUT
≤ 50 mA
0V24_OUT
11.3.7
Digital inputs
Digital inputs
Number of inputs
4 (+ 2)
Input type
PLC-compatible according to EN 61131-2 (digital inputs type 3)
DI01 – DI04: R
i
≈ 4.5 kΩ, sampling cycle ≤ 2 ms
DIO01 – DIO02: R
i
≈ 4.0 kΩ, sampling cycle ≤ 2 ms
Signal level
DC +11 to +30 V
= "1" = Contact closed
DC -3 to +5 V
= "0" = Contact open
Sensor/actuator supply
DC 24 V to EN 61131-2,
External-voltage-proof and short-circuit proof
Maximum line length
30 m
Permitted total current for
internal supply
250 mA (total of all connected sensors/actuators, maximum individual load:
250 mA)
Permitted total current for
external supply
500 mA (total of all connected sensors/actuators, maximum individual load:
500 mA)
25945475/EN – 04/2019