8
Service
Description of status and operating displays
Operating Instructions – MOVIGEAR
®
performance
158
LED
Operating status/
Meaning
Measure
Fault
code
Subfault code
Red
Steady light
1
1, 2
Output stage monitoring fault
Contact SEW-
EURODRIVE
Service.
4
2
Brake chopper fault
7
2
DC link fault
9
3, 4, 8
Control mode fault
10
2, 99
Data Flexibility fault
11
7, 8
Temperature monitoring fault
13
1, 3, 6, 7, 8, 9, 11,
13, 15, 22, 23
Encoder 1 fault
16
2, 11, 12. 30
Startup fault
17
7
Internal processor fault
18
1, 3,4, 7, 8, 9, 10,
12, 13
Software error
20
1.7
Device monitoring fault
21
1
S-Drive 1 fault
23
5, 6, 7, 8
Power section fault
25
10, 12 – 19, 50, 51,
81
Parameter memory monitoring
28
13
FCB drive function fault
33
1, 2, 6, 7, 8, 10
System initialization fault
46
1
Safety card fault
"L/A" LEDs (left)
LED
Meaning
Green
Illuminated
There is
no
Ethernet connection to Ethernet port 1.
Yellow
Illuminated
An Ethernet connection exists from Ethernet port 1 to an additional Ethernet con-
sumer.
"L/A" LEDs (right)
LED
Meaning
Green
Illuminated
There is
no
Ethernet connection to Ethernet port 2.
Yellow
Illuminated
An Ethernet connection exists from Ethernet port 2 to an additional Ethernet con-
sumer.