8
Service
Evaluating fault messages
Operating Instructions – MOVIGEAR
®
performance
149
Fault
Possible cause
Measure
Oil leaking from the out-
put-side oil seal
Drive installed in the wrong
mounting position or
breather valve installed in
wrong position.
Short-term oil and/or
grease leakage at the oil
seal is possible in the run-
in phase (24 hours running
time).
Install the breather valve
correctly
Drive shaft does not turn
although the motor is
running (see chapter
"Meaning of LEDs")
Shaft-hub connection in the
gear unit interrupted
Send in the drive unit for
repair
8.2
Evaluating fault messages
8.2.1
MOVISUITE
®
The following section shows a sample evaluation of a fault message in MOVISUITE
®
:
1. Open the parameter tree in MOVISUITE
®
.
2. In the parameter tree [6], select the "Status" node.
ð
The
current fault messages
can be found in the "Fault status" [5] group.
ð
Additional information
on the causes for the "Not ready” status can be found
in the "Device status" [4] group.
ð
Information on the
history of the fault messages
can be found in the "Fault
memory" [7] node.
[4]
[5]
[1]
[2]
[3]
[6]
[7]
18014420484540299
[1]
Fault status of the main component
[2]
Fault status of the subcomponent
[3]
Display of the status bits
25945475/EN – 04/2019