6
Startup
DIP switches
Operating Instructions – MOVIGEAR
®
performance
128
6.3
DIP switches
6.3.1
Overview
NOTICE
Damage to the DIP switches caused by unsuitable tools.
Possible damage to property.
•
To set the DIP switches, use only suitable tools, such as a slotted screwdriver
with a blade width of no more than 3 mm.
•
The force used for setting the DIP switches must not exceed 5 N.
The following figure shows the DIP switches of the drive unit:
S1 1 2 3 4 1 2 3 4 S2
On
On
ON
1
2 3
4
S1
ON
1
2 3
4
S2
ON
1
S3
2 3 4 5 6 7 8 9 10
25255124107
DIP switch S1 (PROFINET, EtherNet/IP™, Modbus TCP)
The following table shows the functions of DIP switch S1:
DIP switch
S1
1
2
3
4
Meaning
Direction of
rotation re-
versal
Disable hold-
ing function
without enable
Deactivating
the speed
monitoring
Reserved
ON
On
On
Speed monitor-
ing
off
On
OFF
Off
1)
Off
1)
Speed monit-
oring
on
1)
Off
1)
1) The factory settings are shown in boldface.
Do not alterr the factory setting of the S1/4 DIP switch = OFF.