6
Startup
Startup requirements
Operating Instructions – MOVIGEAR
®
performance
127
NOTICE
Undercutting the minimum switch-off time of the line contactor.
Irreparable damage to the inverter or unforeseen malfunctions.
•
You must observe a minimum switch-off time of 10 s after switching off the
voltage supply.
•
Do not switch the voltage supply on or off
more often than once per minute
.
INFORMATION
•
Before startup, remove the paint protection cap from the LED displays.
•
Before startup, remove the paint protection film from the nameplates.
INFORMATION
•
To ensure fault-free operation, do not disconnect or connect signal cables during
operation.
6.2
Startup requirements
The following requirements apply to startup:
•
You have installed the device correctly both mechanically and electrically.
•
You have performed a correct project planning for the device.
•
Safety measures prevent accidental startup of devices.
•
Safety measures prevent danger to persons or machines.
Required hardware components:
•
PC or laptop with USB or Ethernet interface, see the chapter "PC connection".
Required software:
•
MOVISUITE
®
standard engineering software from SEW‑EURODRIVE.