5
Electrical installation
PC connection
Operating Instructions – MOVIGEAR
®
performance
123
5.12.2
Connection via Ethernet
You can establish a connection between PC and device using Ethernet.
The Ethernet connection allows you to access the implemented electronics web
server.
Connection to X4233_1 or X4233_2 (M12 at the electronics cover)
(Only for designs with electronics cover DFC.0..)
[1]
Ethernet
X4233_1
X4233_2
9007224818780939
[1]
Ethernet connection cable RJ45/M12 (industry standard)
With M12 plug connector, 4‑pin, male, D‑coded
Connection to X42
1)
or X43
1)
(mini IO in the connection box).
(Only for designs with electronics cover DFC.1..)
[1]
Ethernet
X43
X42
9007224818784523
[1]
Ethernet connection cable RJ45/Mini IO
1) in preparation
25945475/EN – 04/2019