5
Electrical installation
Optional plug connector assignment
Operating Instructions – MOVIGEAR
®
performance
110
5.10.6
X2313: DC 24 V output backup voltage
The following table shows information about this connection:
Function
DC 24 V output backup voltage
Connection type
M12, 5‑pin, female, L‑coded, color: light gray
Connection diagram
4
1
PE
3
2
Assignment
No.
Name
Function
1
+24V/L1
DC 24 V output/L1 (for backup mode)
2
0V24/N2
0V24 reference potential/N2
(looped through, not used in the device)
3
0V24/N1
0V24 reference potential/N1 (for backup mode)
4
+24V/L2
DC 24 V connection/L2
(looped through, not used in the device)
PE
FE
Functional earth