5
Electrical installation
Terminal assignment
Operating Instructions – MOVIGEAR
®
performance
76
Assignment
Terminal
No
.
Name
Marking
Function
X1
line terminals
1
L1
Brown
Line connection, phase L1 – IN
2
L2
Black
Line connection, phase L2 – IN
3
L3
Gray
Line connection, phase L3 – IN
11 L1
Brown
Line connection, phase L1 – OUT
12 L2
Black
Line connection, phase L2 – OUT
13 L3
Gray
Line connection, phase L3 – OUT
y
–
PE
–
PE connection
X3
braking re-
sistor termin-
als
1
BR
–
Braking resistor connection
2
BR
–
Braking resistor connection
X9
control ter-
minals
1
F_STO_P1
Yellow
Input STO+
2
F_STO_P1
Yellow
Input STO+
(to loop through)
3
0V24_OUT
–
0V24 reference potential
for DC 24 V auxiliary output
4
24V_OUT
–
DC 24 V auxiliary output
11 F_STO_M
Yellow
Input STO_ground
12 F_STO_M
Yellow
Input STO_ground
(to loop through)
13 24V_IN
–
DC 24 V supply
14 24V_IN
–
DC 24 V supply
(to loop through)
21 F_STO_P2
Yellow
Input STO+
22 F_STO_P2
Yellow
Input STO+
(to loop through)
23 0V24_IN
–
0V24 reference potential
for DC 24 V supply
24 0V24_IN
–
0V24 reference potential
for DC 24 V supply
(to loop through)
X42
fieldbus in-
terface
port 1
1)
1
TX+
–
Transmit line +
2
TX-
–
Transmit line -
3
RX+
–
Receive line +
6
RX-
–
Receive line -
X43
fieldbus in-
terface
port 2
1)
1
TX+
–
Transmit line +
2
TX-
–
Transmit line -
3
RX+
–
Receive line +
6
RX-
–
Receive line -
25945475/EN – 04/2019