4
Mechanical installation
Tightening torques
Operating Instructions – MOVIGEAR
®
performance
63
Screw fitting
Part
number
Content
Size
Outer
cable dia-
meter
Tighten-
ing
torque
EMC cable glands
(stainless steel)
18216366 10 pcs
M16 x 1.5 5 to 9 mm 4.0 Nm
18216382 10 pcs
M25 x 1.5 11 to
16 mm
7.0 Nm
The cable retention in the cable gland must withstand the following removal force of
the cable from the cable gland:
•
Cable with outer diameter > 10 mm: ≥ 160 N
•
Cable with outer diameter < 10 mm: = 100 N
Example
The following figure shows an example. The number and position of the cable entries
depends on the ordered variant.