4
Mechanical installation
Shaft-mounted gear unit with TorqLOC® (customer shaft without contact shoulder)
Operating Instructions – MOVIGEAR
®
performance
46
9. Remove the torque arm from the holding fixture/system structure.
9007220783658891
10. Pull the gear unit off the customer shaft until the stop ring is accessible for fasten-
ing.
9007220783661323
11. Make sure that the position of the stop ring has not changed (see marking).
12. Tighten the stop ring to the appropriate torque.
ð
Standard design: 18 Nm
ð
Stainless steel: 7.5 Nm
25945475/EN – 04/2019