Fault messages with parameterizable response
Operating Instructions – MOVIGEAR
®
performance
151
Fault
Description
Index
no.
Possible fault response
External fault
Here you can set the device re-
sponse to an external fault (e.g.
triggered by terminal or control
word).
8622.5
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Fieldbus – timeout
Here one can set how the device is
to respond to a timeout on the
EtherCAT
®
/SBus
PLUS
(timeout period,
Index 8455.3).
8622.6
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
•
Warning with self-reset
•
Application stop (with out-
put stage inhibit) with self
reset
•
Emergency stop (with out-
put stage inhibit) with self-
reset
•
Inhibit output stage with self
reset
External synchronization
Here you can set the device re-
sponse to loss of external synchro-
nization.
8622.7
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
•
Warning with self-reset
•
Application stop (with out-
put stage inhibit) with self
reset
•
Emergency stop (with out-
put stage inhibit) with self-
reset
•
Inhibit output stage with self
reset
Motor temperature pre-
warning – current para-
meter set
Motor temperature current para-
meter set – prewarning.
8442.5
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage