6
Startup
DIP switches
Operating Instructions – MOVIGEAR
®
performance
129
DIP switch S2 (PROFINET, EtherNet/IP™, Modbus TCP)
The following table shows the functions of DIP switch S2:
DIP
switch
S2
1
2
3
4
Meaning
Local mode
Reserved
Reserved
Reserved
ON
Local mode can be activated
in every drive state.
–
–
–
OFF
Local mode can only be
activated when the output
stage is inhibited
1)
–
–
–
1) The factory settings are shown in boldface.
Do not alter the factory setting of DIP switches S2/2 through S2/4 = OFF.
DIP switch S1 (POWERLINK)
The following table shows the functions of DIP switch S1:
DIP switch
S1
1
2
3
4
Binary coding POWERLINK device address
Bit 2
0
Bit 2
1
Bit 2
2
Bit 2
3
ON
1
1
1
1
OFF
0
0
0
0
DIP switch S2 (POWERLINK)
The following table shows the functions of DIP switch S2:
DIP switch
S1
1
2
3
4
Binary coding POWERLINK device address
Bit 2
4
Bit 2
5
Bit 2
6
Bit 2
7
ON
1
1
1
1
OFF
0
0
0
0
DIP switch S3
The S3 DIP switches on the memory module are reserved.
Do not change the factory setting of the S3 DIP switches = OFF.
25945475/EN – 04/2019