Integrated BW1 braking resistor
The following diagram shows the current-carrying capacity of the BW1 braking resistor
per braking operation:
200
300
400
500
600
[J]
[1]
[2]
[3]
0
100
0
10
50
100
200
500
1000
2000
3000
4000
5000
6000
[c/h]
25291390987
[1]
Deceleration ramp 10 s
[2]
Deceleration ramp 4 s
[3]
Deceleration ramp 0.2 s
c/h
Cycles/hour
Calculation example
The known values are:
•
Average braking power: 144 W
•
Deceleration ramp: 2 s
•
200 brake applications per hour
Calculating the energy from the power of the deceleration ramp:
W
P t
W
W
s
W
J
= ×
=
×
=
144
2
288
25296909835
For the deceleration ramp of 2 s, you can use deceleration ramp [3] (0.2 s) in the dia-
gram. Use the characteristic curve with the shorter deceleration ramp because a
shorter deceleration ramp means more braking energy.
The diagram permits 290 J of braking energy for the 0.2 s deceleration ramp and
200 cycles per hour. In this case, the required 288 J can be dissipated via BW1.