92
Operating Instructions – MOVIGEAR® DAC-B
6
Assigning the slave address using a hand-held programming device
Startup
6.6
Assigning the slave address using a hand-held programming device
(binary slave GLK30A)
Hand-held AS-Interface programming devices offer the following functions:
• Reading out and changing an AS-Interface slave address
• Reading out the AS-Interface profile
• Reading out and changing the data and parameter bits
• Function check and test run.
When using a hand-held programming device, you need a
2-core
connection cable that
fits onto the AS-interface plug connector of MOVIGEAR
®
(see the following figure).
6.6.1
X4271: AS-Interface communication interface
The following table provides information about this connection:
Function
Connection of AS-Interface data cable
Connection type
M12, 4-pole, male, A-coded
Wiring diagram
2384154763
Assignment
No.
Name
Function
1
AS+
AS-Interface data cable (+)
2
n.c.
Not connected
3
AS
−
AS-Interface data cable (
−
)
4
n.c.
Not connected
2
1
4
3
NOTICE
The hand-held programming device may
only
be connected via pins 1 "AS-Interface
+" and 3 "AS-Interface –" with the AS-Interface plug connector. The hand-held
programming device can be damaged if not connected properly.