![SEW-Eurodrive MOVIGEAR DAC B Operating Instructions Manual Download Page 209](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343209.webp)
Operating Instructions – MOVIGEAR® DAC-B
209
13
Deceleration torques DynaStop
®
Technical Data and Dimension Sheets
13.3 Deceleration torques DynaStop
®
2393701003
= Operating range of DynaStop
®
= Impermissible operating range of DynaStop
®
M
th
n
n
max
MGF..2
i
tot
Deceleration torque
MGF..4
MGF..4
/ET
i
tot
Deceleration torque
M
DSP
with n
DSP
(gear
unit shaft speed)
M
DSP
with n
DSP
(gear
unit shaft speed)
[Nm]
[rpm]
[Nm]
[rpm]
3-
stage
55.25
200
2.08
3-
stage
48.00
369
0.83
51.51
189
2.23
42.86
329
0.93
45.03
173
2.55
36.61
281
1.09
42.19
162
2.73
34.29
263
1.17
37.24
143
3.08
28.88
222
1.39
33.02
127
3.48
2-
stage
25.72
200
1.56
28.07
108
4.10
21.82
169
1.83
2-
stage
22.86
89
5.03
19.70
153
2.03
19.81
77
5.81
17.33
134
2.31
18.52
72
6.2
16.36
127
2.44
16.00
62
7.19
13.93
108
2.87
13.60
53
8.46
12.66
98
3.16
12.14
47
9.47
10.97
85
3.65
10.37
40
11.09
8.96
70
4.46
9.71
38
11.84
7.88
61
5.08
8.24
32
13.96
7.44
58
5.38
7.00
27
16.43
6.34
49
6.56
6.25
24
18.40
5.76
45
6.94
5.34
21
21.54
4.99
39
8.02
5.00
19
23.00
= preferred gear ratio